36
Maintenance instructions
•
DINO 260XTD
4.3.12.
Measure hydraulic pressures
1. Connect the pressure gauge to the measuring
point (inlet MP).
2.
Make the oil flow through the relief valve by
driving one of the movements against the end
stop.
3. Read the pressure in the gauge
max. pressure at the operating temperature (40-
60 °C) is:
20-20.5 MPa (200-205 bar)
the turning pressure is 8.0 MPa (80
bar)
If you have to readjust the pressure, secure the new setting with a seal.
4.3.13.
Inspecting the condition and functionality of the operating controls
Check the operating controls of the platform control centre and the chassis control centre:
• check the overall condition of the electric appliances inside the box and spray with
moisture repellent, if necessary
• check the cables and the tightness of the cable clamps
• test the sound signal, the emergency stop and the emergency descent
• test all the movements. Ensure that all the movements stop when the control lever is
released.
Check the condition of the protective covers for the control centres.
Battery for the emergency descent system
The system incorporates an automatic battery recharger with short circuit and overheat
protection.
• output
125 W
• charging voltage 13.7–14.7 V
• rated current
10 A
as necessary, top up battery fluid above the elements