Reference
20
Cleaning
Fluid
Compatibility
Oil- or Water-Based Materials
•
When
spraying
water-based
materi- als, flush the system
thoroughly with water.
•
When spraying
oil-based
materials,
flush the system thoroughly with
min- eral spirits or compatible, oil-
based flushing solvent.
•
To spray
water-based
materials
after spraying oil-based
materials,
flush the system thoroughly with
water first. The water flowing out of
drain tube should be clear and
solvent-free
before
you begin
spraying the water-based mate- rial.
•
To spray
oil-based
materials
after
spraying water-based
materials,
flush the system thoroughly with
mineral spir- its or a compatible oil-
based flushing solvent first. The
solvent flowing out of the drain tube
should not contain any water. When
flushing with solvents always follow
Static Grounding Instructions (Oil-
•
To avoid fluid splashing back on your
skin or into your eyes, always aim gun
at inside wall of pail.
Static Grounding
Instructions (Oil-Based
materials)
Always use a metal pail for oil-based
materials requiring flushing with compatible
oil-based flushing solvents when sprayer is
flushed or pressure is relieved.
Follow local code. Use only conductive metal
pails, placed on a grounded surface such as
concrete.
Do not place pail on a non-conductive surface
such as paper or cardboard which interrupts
grounding continuity.
The equipment must be grounded to
reduce the risk of static sparking and
electric shock. An electric or static spark
can cause fumes to ignite or explode. An
improper ground can cause electric shock.
A good ground provides an escape wire for
the electric current.