How to Spray
11
B
5. When sprayer starts pumping, flushing
solvent and air bubbles will be purged
from system. Allow fluid to flow out of
drain tube, into waste pail, for 30 to 60
seconds.
6. Turn ON/OFF switch to
OFF
position.
High-pressurespray isable to inject toxins
into the body and cause serious bodily
injury. Do not stop leaks with hand or rag.
7. Inspect for leaks. If leaks occur, per-
form
, page
9, then tighten all fittings and repeat
. If there are no leaks continue
with the next step.
Fill Pump
1. Move suction tube to paint pail and
submerge suction tube in paint.
NOTE:
Some fluids may prime faster
if the ON/OFF Switch is momentarily
turned off so the pump can slow and
stop. Turn ON/OFF switch on and off
several times if necessary.
Fill Gun and Hose
1. Hold gun against waste pail. Point
gun into waste pail.
a. Disengage trigger lock.
b. Pull and hold gun trigger.
c. Turn Prime/Spray valve
horizontal to SPRAY position.
d. Turn ON/OFF switch to
ON
posi- tion.
A
C
D
2. Turn ON/OFF switch to
ON
position.
3. Wait to see paint coming out of drain
tube.
4. Turn ON/OFF switch to
OFF
position.
2. Trigger gun into waste pail until
only paint comes out of the gun.
3. Release trigger. Engage trigger lock.
4. Transfer drain tube to paint pail and
clip to suctiontube.
NOTE:
When motor stops, sprayer is
ready to paint. If motor continues to run,
sprayer is not properly primed. Repeat
and
.
Start Up