Dini Argeo LTP Installation And Operating Instructions Manual Download Page 1

www.diniargeo.com

LTP

Forklift hydraulic weighing system

ENGLISH

INSTALLATION AND OPERATING INSTRUCTIONS

Summary of Contents for LTP

Page 1: ...www diniargeo com LTP Forklift hydraulic weighing system ENGLISH INSTALLATION AND OPERATING INSTRUCTIONS...

Page 2: ......

Page 3: ...bracket for the indicator in the cabin 8 Reference stickers 8 Kit installation 10 Before installation 10 Sensor installation 11 Installing the indicator 12 Applying reference stickers 14 Calibration 1...

Page 4: ...r any additional information or specific requests please contact your local dealer This publication is optimised for A4 printing Introduction Weighing system specifications POWER SUPPLY 5 Vdc via exte...

Page 5: ...ly be carried out by personnel authorised by Dini Argeo Dini Argeo is not responsible for any weighing errors resulting from improper use of the system For proper operation of the system the forklift...

Page 6: ...from the forklift battery via optional internal power supply 5 key keypad and LCD Vertical tilt can be adjusted via the integrated bracket The LTP kit consists of Weight indicator Pressure sensor Fix...

Page 7: ...odes this indicates that a specific function is active 11 Weight acquisition phase Key Description For numerical entries decreases the value If pressed for a long time 2 sec it allows you to set the b...

Page 8: ...Pressure sensor Stainless steel sensor IP65 protection rating and hydraulic connector with 1 4 inch parallel PSB female Sensor dimensions length 73 5 mm diameter 24 5 mm 4 Reference stickers Stickers...

Page 9: ...supply unit is present 5 Power supply unit optional 6 Thermal printer optional The appropriate optional ALxxV5 power supply unit with 18 to 72Vdc or 40 to 160Vdc input can be chosen according to the v...

Page 10: ...r than the maximum value indicated on the sensor datasheet 4000 psi 280 bar Remove the pressure in the hydraulic circuit this can be done in two ways A Lower the forks to their maximum and move forwar...

Page 11: ...n the pressure pipe that guides the cylinder the sensor should be positioned as close as possible to the cylinder The sensor must be installed with the cable pointing downwards This prevents air from...

Page 12: ...e glands Installing the indicator FIND A SUITABLE LOCATION FOR THE INDICATOR INSTALLING THE INDICATOR BRACKET Adjust the orientation of the indicator vertically and horizontally so that it is clearly...

Page 13: ...to the instrument before performing any operation Keep the cable length as short as possible Avoid running the cable near heat sources Make sure that the cable does not get caught in the moving parts...

Page 14: ...the forklift plate and the rectangular sticker to the upright These stickers identify the reference area perform all weighing operations when the arrowhead is inside the yellow band The operator must...

Page 15: ...IC CIRCUIT The presence of air in the hydraulic circuit can worsen the accuracy of the system To remove it set the forks to the maximum height twice 2 GO TO THE PROGRAMMING MENU Press while the power...

Page 16: ...TIMES WITH LTPTOOL 4 1 Select the Settings tab and select the serial port Click on Connect Set the number of up down cycles default 5 By increasing the number of cycles the procedure becomes longer bu...

Page 17: ...timized layout for A4 print TECH_MAN_ENG_LTP 4 3 Click on Start and follow the instructions in the box in the bottom left 4 4 The times to be used during calibration are shown at the end of the acquis...

Page 18: ...s The highest possible calibration weight must be used for the first calibration ideal condition sample weight maximum capacity It will not be possible to acquire a weight greater than the value enter...

Page 19: ...the system is found to be inaccurate below 500 kg after testing HOW TO ADD A CALIBRATION POINT 1 Lift the weight value you want to acquire e g 500 kg with the indicator in the weighing state The indic...

Page 20: ...nf Number of divisions within which the weight remains in hold state If the weight respect to the last acquired weight does not exceed the number of divisions set in DIV UNF the indicator will continu...

Page 21: ...d of fork ascent and start of acquisition Used to delay the acquisition of the weighing tim avG Weight acquisition time The weight is obtained by averaging the values acquired during the set time Acce...

Page 22: ...Adjusting the display 39 Factory configuration reset 40 Advanced calibration 23 Configuration of the serial ports 26 Auto switch off 40 Diagnostics 41 Screen saver 40 Advanced 42 Parameter visible onl...

Page 23: ...G autoff 0 Cal Cal adv B 0 Cal GRAV sure ok 5 RanGe2 6 Zero 1 CAL PAR 2 metrol 4 Cal man 3 Cal ADj 2 DIV 3 U M 1 DECIM 4 RanGe1 TECH_MAN_ENG_LTP Calibration parameters Configuration of the decimal poi...

Page 24: ...AC G kG t lb C 1 3 K C Cal adV E D A B F H Scr Sav I reset J diaG G autoff TECH_MAN_ENG_LTP Scale capacity Set Max or Range 1 Max range 800 000 Range 2 For multirange scales set the second weighing ra...

Page 25: ...ower f cal ok oK 000000 i TECH_MAN_ENG_LTP Metrological parameters Page 15 Page 15 Enter Browse Save and exit Filter configuration Stability detection sensitivity 0 99 For use by the manufacturer For...

Page 26: ...DE serial Com PC i i baud D 1 2 Com Sel Com2 Com1 TECH_MAN_ENG_LTP Page 15 Page 15 Enter Browse Save and exit On demand Transmission at the pressure of Configuration of the serial ports Selection of t...

Page 27: ...l adV Scr Sav reset diaG autoff 1 2 3 Com pC Com Prn advanC Com sel bit baud MoDE 1 2 3 4 bit D 1 3 baud 1200 115200 9600 mode D 1 4 bit n 8 1 n 8 2 e 7 2 TECH_MAN_ENG_LTP Page 15 Page 15 Enter Browse...

Page 28: ...1 Off 2 On 3 C i i G H I J K A B C D E F Cal adV Scr Sav reset diaG autoff 1 2 3 Com pC Com Prn advanC baud Cts bit 1 2 3 Com Prn TECH_MAN_ENG_LTP Communication speed Baud rate Configuration of the s...

Page 29: ...time 1 Off 2 On 3 C i i G H I J K A B C D E F Cal adV Scr Sav reset diaG autoff 1 2 3 Com pC Com Prn advanC baud Cts bit 1 2 3 TECH_MAN_ENG_LTP Printer control signal Free adjustment Characters sent 0...

Page 30: ...erM short no yes Cr Crlf i protoC D 3 4 iGnore No yes i TECH_MAN_ENG_LTP Page 15 Page 15 Enter Browse Save and exit Advanced configurations Communication protocol TTL port for use by the manufacturer...

Page 31: ...header data tiCket barC 39 end tiC barC l Char weiGhs CloCk Copies barC up b line barC h barC dt test lanG 1 2 3 4 5 6 7 13 8 14 9 15 10 11 12 16 1 Off 2 On 3 C i i G H I J K A B C D E F Cal adV Scr...

Page 32: ...9 end tiC barC l Char weiGhs CloCk Copies barC up b line barC h barC dt test lanG 1 2 3 4 5 6 7 13 8 14 9 15 10 11 12 16 1 Off 2 On 3 C i i G H I J K A B C D E F Cal adV Scr Sav reset diaG autoff TECH...

Page 33: ...1 12 16 1 Off 2 On 3 C i i G H I J K A B C D E F Cal adV Scr Sav reset diaG autoff TECH_MAN_ENG_LTP First row of header Visible only on line 2 line 3 and line 4 Print customisation Print header Enable...

Page 34: ...x 46 61 76 L 91 106 j 121 y MENU H E L L O H E L L O 01 032 02 032 03 032 Print delete ok ok 072 069 076 076 079 032 01 032 02 032 04 032 03 032 05 032 24 032 032 06 032 Enable line 2 line 4 line 1 li...

Page 35: ...t lanG 1 2 3 4 5 6 7 13 8 14 9 15 10 11 12 16 1 Off 2 On 3 C i i G H I J K A B C D E F Cal adV Scr Sav reset diaG autoff TECH_MAN_ENG_LTP Selection of the weight data Progressive weighed Receipt label...

Page 36: ...F Cal adV Scr Sav reset diaG autoff TECH_MAN_ENG_LTP Date and time Bar code 39 Barcode top margin mm If mode tiCket 0 9 If mode tiCket 1 99 If mode tiCket 1 99 Barcode left margin mm Barcode height m...

Page 37: ...t test lanG 1 2 3 4 5 6 7 13 8 14 9 15 10 11 12 16 1 Off 2 On 3 C n 1 3 i i G H I J K A B C D E F Cal adV Scr Sav reset diaG autoff TECH_MAN_ENG_LTP Selection of the weight data Multi copy prints Pape...

Page 38: ...C 39 end tiC barC l Char weiGhs CloCk Copies barC up b line barC h barC dt test lanG 1 2 3 4 5 6 7 13 8 14 9 15 10 16 11 12 1 Off 2 On 3 C i i G H I J K A B C D E F Cal adV Scr Sav reset diaG autoff T...

Page 39: ...to brGt1 brGt5 no yes loCk briGht 1 2 3 1 Off 2 On 3 C i i G H I J K A B C D E F Cal adV SCr Sav reset diaG autoff TECH_MAN_ENG_LTP Adjusting the display Backlighting Brightness Display lock for use b...

Page 40: ...D E F Cal adV Scr Sav reset diaG autoff i TECH_MAN_ENG_LTP Auto switch off How to set the value How to set the value Function for restoring default configurations keeping the stored calibration Screen...

Page 41: ...P Diagnostics Display Integrity check of all segments and icons Keypad Press any key to check its correct operation with beep and code on display CTS Check of status of the control signal from the pri...

Page 42: ...adV Scr Sav reset diaG autoff 1 loCk kb 4 3 5 pin teC pin use dflt t TECH_MAN_ENG_LTP Access PIN to programming menu Access PIN for sub menu din wGt of the user menu Permanent keyboard lock excluding...

Page 43: ...terminator characters ASCII 013 and ASCII 010 011ST 0 0 PT 20 8 0 kg CR LF where 01 Code 485 of the instrument 2 characters only if communication mode 485 is enabled 1 ASCII 049 character ST Scale sta...

Page 44: ...XC CELL2 CELL4 CELL3 CELL1 J2 J2 SENSE 5V GND COM 1 COM 1 J 1 J 1 Legal Internal use B A GND RX CTS TX RS232 RS485 RS232 I O BOARD CLOCK ALIBI MEMORY 01 02 J4 ON 5V GND J 1 CAL RS232 COM 2 SENSOR BOOT...

Page 45: ...e scale When acquiring the calibration points use the increasing calibration weights Er 37 Calibration error Repeat the calibration checking that the capacity and division have been correctly set Er 3...

Page 46: ...ommunication speed Baud rate 28 Communication speed Baud rate 27 Configuration of the serial protocol 28 TTL port for use by the manufacturer 30 Configuration of the serial protocol 27 Printer control...

Page 47: ...41 Permanent keyboard lock excluding key 42 Access PIN to programming menu 42 Factory configuration reset 40 Diagnostics 41 Advanced 42 Auto switch off 40 Backlighting 39 Brightness 39 Paper outlet f...

Page 48: ...Optimized layout for A4 print 48 TECH_MAN_ENG_LTP Notes...

Page 49: ...49 Optimized layout for A4 print TECH_MAN_ENG_LTP...

Page 50: ...Optimized layout for A4 print 50 TECH_MAN_ENG_LTP...

Page 51: ......

Page 52: ...1784 Fax 39 0536 926654 www diniargeo com The information in this document is approximate and can be subject to variations without prior notice by Dini Argeo in compliance with the norms in force The...

Reviews: