DOSAGE
44
If the total weight of the various loading activities exceeds the maximum dosable weight (
MAXIMUM
DOSABLE WEIGHT
step
), the instrument calculates the number of consecutive repetitions which it
must execute in order to reach the set total weight.
By examining the previous example, if the maximum dosable weight would have been equal to 800kg, the
instrument would execute 2 consecutive repetitions of the following formula:
BASIC FORMULA
RECALCULATED FORMULA
ACTIVITY
BASIC TARGET
ACTIVITY
RECALCULATED TARGET
Component 1
20 Kg
Component 1
100 Kg
Component 2
15 Kg
Component 2
75 Kg
Component 3
40 Kg
Component 3
200 Kg
Component 4
25 Kg
Component 4
125 Kg
Furthermore:
- After each repetition the instrument corrects the weight to be dosed for each activity of the following
cycle, on the basis of the quantity that has been dosed in the previous cycle.
- It is possible to decide to execute the fine dosage for each activity always in each cycle or only in the last
cycle, by setting the
SLOW EXECUTION MODE
(
). This is useful if one wants to dose at maximum
speed in every cycle, and manage the slow speed (fine dosage) only in the last cycle.
- With various dosage cycles, the instrument executes the set repetitions with the same quantity of
material.
ENTERING THE TOTAL WEIGHT:
1)
Press the
button
2)
Enter the total weight to be dosed (the display will show the database’s unit of measure).
3)
Confirm with OK key.
4)
START the DOSAGE.
5)
The instrument will automatically execute all the necessary dosage repetitions in order to dose the
total quantity of the set material
NOTES:
- With an approved instrument, one should give a start impulse between one dosage and
another.
- The set total weight is cleared upon each selection of the formula.
- In this functioning mode, it’s not possible to use the dosage cycle repetition function.
6.12.3
First free component
If the “FIRST FREE COMPONENT” functioning mode has been enabled in the set-up it is possible to have two
different kinds of activities as first activity: manual dosage or manual weight; on the basis of the dosed or
known quantity of material, the instrument recalculates the weights to be dosed of all the following loading
activities which make up the formula, proportionally to the target of the basic formula.
The first activity of the formula must be a manual dosage or manual weight;
otherwise, the "ERROR:
WRONG FIRST ACTIVITY" message will be displayed and it will not be possible to carry out the formula.