3590EKR, 3590EXP, 3590EXT, CPWE, CPWET series indicator
E-AF09_02_16.03_EN_U
40
13.2.3 AUTOMATIC DYNAMIC AXLE WEIGHING
13.2.3.1 CONFIGURATION
-
Set parameter SETUP
F.ModE >> totAL >> AXLE W (RIF.MAN.T.)
on
“dYnAMi”
.
If before was setted the
MANUAL
or
STATIC
axles weighing, the indicator ask to set the filter of this weighing mode,
press
FN/ENTER
to confirm.
For a correct functioning one should correctly set the weighing parameters in the
F.Mode >> total >> DYN.CFG
menu of the Set-up environment or by a direct function 605, linked to a key.
(See the TECHNICAL MANUAL)
:
1.
”Min.Wei”
(Minimum weigh of the axle);
2.
”n.SMPLS”
(Average weight samples);
3.
“tiME W”
(Interval between cycles);
4.
”Skip B.”
(Beginning axles to skip);
5.
“Skip E.”
(Ending axles to skip);
6.
”Err.En”
(Axle acquisition error enable);
7.
“SPEEd”
(Speed Limit in Km/h);
8.
”Tim.Out”
(Axle acquisition time out).
9.
“PL.Widt”
(Platform width);
13.2.3.2 WEIGHING PROCEDURE
-
As soon as the indicator has completely turned on and enters in the weighing status, it waits for the first axle and the
indicator displays:
3590E
LED display
LCD display
CPWE
[In which:
XXXXXX
is the current weight on the scale]
-
Select, if requested, the customer / material / vehicle to be linked to the weigh.
-
Transit with the first axle of the vehicle on the scale in the limits of speed setted in the
DYN.CFG >> SPEED
,
avoiding braking while transiting on the scale.
-
The axle will be acquired automatically if:
1)
The weight is greater than the set minimum weight of the axle setted in
<<Min.Wei>>
step.
2)
The detected weight is within the parameters of the dynamic weigh, which are set in
<<DIN.CFG>>
,
(TECH.MAN.REF.)
.
-
After the weight of the first axle is acquired, the indicator emits a sound and displays for an instant the following
message:
XXXXXX
CUS MAT VEH
WAIT AXLE 1
1
CUS MAT VEH
WAIT AXLE 1
SET FILTER ?