OPERATOR’S MANUAL
with Maintenance Information
Maintenance
47
5
Start the engine from the ground controls
and raise the platform approximately 5.5m
from the ground.
6
Release the safety arm latch, lift the safety
arm and rotate up to a vertical position.
7
Lower the platform onto the safety arm.
Stop the engine.
Crushing hazard. Keep
hands clear of the safety arm when lowering
the platform.
8
Inspect the center chassis area and
scissor arms for burnt, chafed and pinched
cables.
9
Inspect the following areas for burnt,
chafed, corroded, pinched and loose
wires:
· Scissor arms
· ECM to platform controls
· Power to platform wiring
10 Inspect for a liberal coating of dielectric
grease in all connections between the
ECM and the platform controls.
11 Raise the platform and return the safety
arm to the stowed position.
12 Lower the platform to the stowed position
and turn the machine off.
B-3
Check the Exhaust System
Dingli requires that this procedure be
performed every 250 hours or quarterly,
whichever comes first.
Maintaining the exhaust system is essential to
good engine performance and service life.
Running the engine with a damaged or leaking
exhaust system can cause component
damage and unsafe operating conditions.
Bodily injury hazard. Do not
inspect while the engine is running. Remove
the key to secure from operation.
Bodily injury hazard. Beware
of hot engine components. Contact with hot
engine components may cause severe burns.
1
Open the cover.
2
Be sure that all fasteners are tight.
3
Inspect all welds for cracks.
4
Inspect for exhaust leaks; i.e., carbon
buildup around seams and joints.
Summary of Contents for JCPT2223RTA
Page 2: ...OPERATOR S MANUAL with Maintenance Information Version of the Record 1 ...
Page 3: ......
Page 5: ......
Page 7: ......
Page 19: ...OPERATOR S MANUAL with Maintenance Information Decals 12 ...