Dinex DXIDPC20120 Operating Manual Download Page 1

Convection Heated Plate and Base 

Dispensers Operating Manual 

 © 2011 DINEX | CARLISLE 

4711 EAST HEFNER ROAD, OKLAHOMA CITY, OK 73131

WWW.DINEX.COM

For Service Information call 1.888.673.4639

Please provide following information:

• Model number
• Serial number
• Part Description and number as shown in parts list

Manual No. Plate_Base_Heater_0411

Model:

 

DXIDPC20120

DXIDPC30180

DXIDWB20900

DXIDWB30900

DXIDPWB20900

For Equipment with Serial 

110613B and Newer.

SECTION 1: INTRODUCTION
Introduction ..............................................................................2
SECTION 2: GENERAL INFORMATION
Information...............................................................................2
SECTION 3: INSTALLATION 
Set Up ..................................................................................2-3
Electrical ..................................................................................3
SECTION 4: OPERATING INSTRUCTION
Start Up  ..................................................................................3
SECTION 5: PROGRAMMING
Programming ...........................................................................4

SECTION 6: ALARMS
Alarms .....................................................................................5
SECTION 7: MAINTENANCE
Cleaning ..................................................................................5
SECTION 8: TROUBLESHOOTING
Problem/Possible/Remedy Chart ............................................5
SECTION 9: REPLACEMENT PARTS
Chart ........................................................................................6
SECTION 10: PARTS CHART
Base Dispenser Assembly Diagram ........................................7
Plate Dispenser Assembly Diagram ........................................8
Wiring Diagrams .................................................................9-11
WARRANTY ..........................................................................12

Plate or Base Heater: 

DO NOT DISCARD

Summary of Contents for DXIDPC20120

Page 1: ...0900 DXIDPWB20900 For Equipment with Serial 110613B and Newer SECTION 1 INTRODUCTION Introduction 2 SECTION 2 GENERAL INFORMATION Information 2 SECTION 3 INSTALLATION Set Up 2 3 Electrical 3 SECTION 4 OPERATING INSTRUCTION Start Up 3 SECTION 5 PROGRAMMING Programming 4 SECTION 6 ALARMS Alarms 5 SECTION 7 MAINTENANCE Cleaning 5 SECTION 8 TROUBLESHOOTING Problem Possible Remedy Chart 5 SECTION 9 REP...

Page 2: ...noted on freight bill and signed by person making delivery A freight claim should be filed immediately with the transportation company If damage is unnoticed or concealed until equipment is unpacked notify the transportation company immediately and tell them you want to file a concealed damage claim This must be done within fifteen 15 days after delivery was made Be sure to retain all packing mate...

Page 3: ...once the unit is turned on The fan motor will begin to circulate the heated air in and around the plates bases in a convection process that promotes a quick and even heat absorption by the plates bases Once the air inside the cabinet has reached the desired and preset temperature the thermostats will continue to maintain this temperature by regulating the power to the heating element The fan motor...

Page 4: ...n revise the Preheat time Ready Delay time Preheat heater temperatures and Ready Delay heater temperatures To set the time settings press the Time button for approximately 5 seconds the display will alternate PrE Ht and the current setting The LEDs will be off Press either the UP or DOWN setting button to change the time When done press the Time button and the display will alternate rdY Ht and the...

Page 5: ...dispenser 2 Clean off debris Unit heats but fan does not blow 1 Defective motor 2 Jammed or loose fan blade 3 Loose wiring 1 Replace motor 2 Replace or tighten blade 3 Determine fault correct Unit does not operate and power indicator light does not come on 1 No power 2 Open Hi Limit 3 Defective power switch 4 Loose wiring 1 Make sure plug is connected switch is ON 2 Check for power to receptacle 3...

Page 6: ...3015267 3 5IN CASTER W BRAKE 2 9 DX183015266 3 5IN CASTER 2 10 DX183050011 CORNER BUMPER BLACK 4 11 DX186000054 MANUAL RESET HI LIMIT 1 12 1 13 DX186120404 1600W ELEMENT 2 14 DX186140345 FAN WHEEL 2 Description Part Number Quantity 15 DX186140372 208 240V MOTOR 2 16 DX186160241 POWER SUPPLY BOARD 1 17 1 18 DX186070017 TERMINAL BLOCK 1 19 DX186160340 PROBE W CONECTOR 1 20 DX186160343 PROBE W CONECT...

Page 7: ...Dispenser Assembly 1 DX186170087 DISPENSER BUSHING 4 2 DX186170489 DISPENSER PULLEY 8 3 DX184002015 DISPENSER SPRING 9 Description Part Number Quantity 6 DX160953128 BASE DISPENSER ASSEMBLY 1 Description Part Number Quantity Pulley bracket DX165052092 ...

Page 8: ...nser 8 Plate Dispenser Assembly 1 DX186170087 DISPENSER BUSHING 4 2 DX186170489 DISPENSER PULLEY 8 3 DX184002015 DISPENSER SPRING 6 Description Part Number Quantity 7 DX160953120 PLATE DISPENSER ASSEMBLY 1 Description Parts Number Quantity ...

Page 9: ... and Base Dispenser 9 Wiring Diagram Model DXIDPWB20900 CAUTION Disconnect power before servicing or resetting high limit thermostats NOTE All wires to be 10 Awg high temperature silicone insulated unless otherwise specified ...

Page 10: ...ase Dispenser 10 Wiring Diagram Models DXIDPC20120 DXIDWB20900 CAUTION Disconnect power before servicing or resetting high limit thermostats NOTE All wires to be 10 Awg high temperature silicone insulated unless otherwise specified ...

Page 11: ...ase Dispenser 11 Wiring Diagram Models DXIDPC30180 DXIDWB30900 CAUTION Disconnect power before servicing or resetting high limit thermostats NOTE All wires to be 10 Awg high temperature silicone insulated unless otherwise specified ...

Page 12: ...nt This exclusive remedy shall not have failed of its essential purpose as that term is used in the Uniform Commercial Code as long as Dinex remains willing to repair or replace defective Warranted Products within a commercially reasonable time after being notified of Customer s warranty claim LIMITATIONS THESE WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER WRITTEN ORAL EXPRE...

Page 13: ...NOTES Convection Heated Plate and Base Dispenser 13 ...

Page 14: ... 2011 DINEX CARLISLE 4711 EAST HEFNER ROAD OKLAHOMA CITY OK 73131 WWW DINEX COM Manual No Plate_Base_Heater_0411 ...