THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE

Important Safety Advice

DO NOT COVER OR OBSTRUCT the air inlet or outlet 
grille.
IMPORTANT – Disconnect from the mains supply 
before carrying out maintenance work.
THIS APPLIANCE MUST BE EARTHED
This heater must not be located immediately above 
or below a fi xed socket outlet or connection box.
Keep combustible materials such as drapes and 
other furnishings clear from the front, sides and rear 
of the heater.
DO NOT use this heater in the immediate surrounding 
of a bath, a shower or a swimming pool.
DO NOT use this heater in areas where excessive 
dust exists.
This appliance is not intended for use by children 
or other persons without assistance or supervision 
if their physical, sensory or mental capabilities 
prevent them from using it safely. Children should 
be supervised to ensure that they do not play with 
the appliance.

  The heater carries the Warning symbol 

indicating that it must not be covered.

The instruction leafl et belongs to the appliance and 
must be kept in a safe place. If changing owners, the 
leafl et must be surrendered to the new owner.
IMPORTANT – If the mains lead of this appliance is 
damaged, it must be replaced by the manufacturer 
or its service agent or a similarly qualifi ed person in 
order to avoid a hazard.
Ensure proper manual handling procedures are 
observed at all times.

General

SRX180

SRX140

SRX120

SRX80

Heat 

Output* 

(kW)

2

1800

1400

1200

800

Dimensions 

L x H x D 

(mm)

911x500x145 740x500x145 670x500x145 503x500x145

Power Input 

(W)

3

50-53

56-60

43-47

26-27

2

33-35

36-40

29-32

19-20

1

23-24

24-26

20-22

16-17

Air Flow 

Rate 

(m

3

/hr)

3

540

410

345

228

2

300

225

190

125

1

160

120

100

60

Sound 

Level @ 1m 

dB(A)

3

47

47

47

47

2

38

38

38

38

1

27

27

27

27

Voltage 

(V) 

~230-240

~230-240

~230-240

~230-240

* Rated Output at 45°C at medium fan setting.

UK

- 1 -

Dimplex SmartRad

Models: SRX80, SRX120, SRX140 & SRX180

The SmartRad convector is an intelligent convector designed 
for use on central heating systems in homes and commercial 
environments. The convector is optimised to work with the 
Dimplex range of heat pumps and also works effi ciently on 
standard oil or gas fi red central heating systems.

Some of the appliance’s features are highlighted in Fig.1.

(a)  Aesthetic Front Panel

(b)  Thermostat/ Fan selector Panel

(c)  Metal air outlet grille

(d)  1m long cable

To ensure optimum performance consideration must be 
given to the size of fan convector and the heating system 
design. The following should be considered:

These appliances have to be only used on closed 

• 

circulation, two pipe central heating systems.

Appliances should be correctly sized to match the heat 

• 

loss requirements of the room. Kitchens, living areas etc, 
should be based on the medium setting, while bedrooms 
should be based on the low speed.

Installation Instructions.

Unpack the appliance.

Remove all packaging from the appliance. Remove the four 
fi xing screws at the bottom of the appliance as shown in 
Fig. 2 to release the front cover. Put the front cover to one 
side to avoid damage during installation.

Wall mounting.

Using the Fig 3, mark off and drill four holes in a suitable 
solid wall. Insert the wall plugs (provided) into all the holes. 
Screw in the top two screws to almost full way. Hang the 
appliance on these top screws. Screw in the bottom two 
screws to secure. Tighten the top screws. For drywalls, 
use suitable wall plugs (not supplied) and repeat as above. 
The appliance should be securely mounted to the wall to 
mimimise the possibility of noise transmission.

Water connection.

The heating system should be capable of supplying hot 
water to the appliance. Therefore the following should be 
noted

The minimum pipe work should be 15mm

 

Appliances are not suitable for use on microbore pipes

 

Appliances are not suitable for use on one pipe 

 

systems.

Where the appliance is fi tted onto a system with other 

 

emitters, a separate circuit for the appliances should be 
considered to ensure an adequate water fl ow  through 
it.

Optimum performance of the appliance will require 

 

balancing of the whole system.

Summary of Contents for SmartRad SRX120

Page 1: ...h may be of use to you and is available 24 hours a day It includes Operating and installation instructions Easy How to use guides for storage heaters Service and repairs Where to buy our products Literature downloads Heating requirement calculator Visit www dimplex co uk support A division of GDC Group Ltd Millbrook House Grange Drive Hedge End Southampton SO30 2DF www dimplex co uk Registered No ...

Page 2: ...126 0 Issue 0 UK DE The product complies with the European Safety Standards EN60335 2 30 and the European Standard Electromagnetic Compatibility EMC EN55014 EN60555 2 and EN60555 3 These cover the essential requirements of EEC Directives 2006 95 EC and 2004 108 EC FR NL ...

Page 3: ...1 4 5 3 Model A B C D SRX80 503 324 396 386 SRX120 670 492 564 564 SRX140 740 562 634 624 SRX180 911 732 804 794 2 SRX80 All dimesnsions in mm ROOM NTC WATER NTC 02 4 2 A E L M B R G D E N F H ...

Page 4: ...6 SRX120 SRX140 SRX180 ROOM NTC WATER NTC 02 4 2 A E L M B R G D E N F H H A F SPEED 1 SPEED 2 PILOT WIRE M C D E G I R 02 4 2 B ...

Page 5: ...3 1378 1 411 691 955 1251 3 806 1394 2016 2668 3 689 1164 1557 2070 2 591 1010 1447 1894 2 530 894 1215 1606 1 379 641 907 1174 1 357 599 828 1083 3 587 1012 1460 1926 3 530 902 1190 1580 2 413 704 1005 1309 2 387 655 884 1163 1 237 399 564 728 1 231 387 534 694 35 C 45 C 55 C 65 C 35 30 C 45 40 C 55 47 C 65 50 C 3 551 918 1284 1649 3 1495 2856 3925 4628 2 487 812 1136 1460 2 893 1760 2424 2879 1 ...

Page 6: ...UK 1 DE 4 FR 7 NL 10 ...

Page 7: ......

Page 8: ...s an intelligent convector designed for use on central heating systems in homes and commercial environments The convector is optimised to work with the Dimplex range of heat pumps and also works efficiently on standard oil or gas fired central heating systems Some of the appliance s features are highlighted in Fig 1 a Aesthetic Front Panel b Thermostat Fan selector Panel c Metal air outlet grille ...

Page 9: ...ce with the following code BROWN LIVE L BLUE NEUTRAL N BLACK PILOT WIRE GREEN YELLOW EARTH E Pilot Wire Connection The BLACK control wire is designed to carry a signal from slot in or wall mounted Dimplex programmers If however a programmer is not being used the pilot wire should be isolated in accordance with the current IEE Wiring Regulations IMPORTANT DO NOT connect the BLACK pilot wire to eart...

Page 10: ...UPPLY before carrying out any cleaning or maintenance General cleaning External appearance can be maintained by wiping occasionally with a damp cloth for stain removal weak soap solution can be applied then wipe dry Internal cleaning and maintenance From time to time it may be necessary to remove the front from the unit so that the interior of the heater and the heater compartment can be cleared o...

Page 11: ... eine zentrale Heizungsanlage in Privat und Geschäftshäusern vorgesehen ist Der Konvektor wurde für den Einsatz im Kombination mit Dimplex Wärmepumpen optimiert funktioniert aber auch hervorragend an Zentralheizungen mit herkömmlicher Öl oder Gasfeuerung Abb 1 zeigt einige Leistungsmerkmale des Geräts a Ansprechende Front b Thermostat Gebläse Einstellung c Metall Jalousieauslass d 1 m langes Kabel...

Page 12: ...chlossen werden dass durch eine Gerätebewegung kein Kurzschluss entsteht WICHTIG Die einzelnen Leiter des Netzkabels sind folgendermaßen farblich gekennzeichnet BRAUN PHASE L BLAU NULL N SCHWARZ STEUERLEITUNG GRÜN GELB ERDE E Steuerleitungsanschluss Die SCHWARZE Steuerleitung ist für einsteckbare oder wandmontierte Dimplex Programmiergeräte vorgesehen Wird jedoch kein Programmiergerät verwendet mu...

Page 13: ...statventile an den Heizkörpern zudrehen Verschmutzter Wärmetauscher Reinigung und Wartung WARNUNG Vor dem Reinigen oder Warten immer VOM STROMNETZ TRENNEN Reinigung allgemein Durch gelegentliches Abwischen mit einem feuchten Tuch von außen sauber halten Zum Beseitigen von Flecken zuerst mit einer milden Seifenlauge abwischen und anschließend trocken wischen Reinigung und Wartung von innen Ab und z...

Page 14: ...al des foyersetdesenvironnementscommerciaux Ceconvecteurest optimisé pour fonctionner avec la gamme Dimplex de pompes à chaleur et fonctionne efficacement dans les systèmes de chauffage central à pétrole ou à gaz standards Certaines des caractéristiques de l appareil sont illustrées sur la Fig 1 a Panneau avant esthétique b Thermostat Panneau du sélecteur de ventilateur c Grille de sortie d air mé...

Page 15: ... Carte de circuit imprimé des commandes M Moteur R Résistance Tous les câbles doivent être connectés pour que les éventuels mouvements de l appareil ne provoquent pas de court circuit IMPORTANT Les codes couleurs des câbles de branchement sont les suivants MARRON ACTIF L BLEU NEUTRE N NOIR CÂBLE PILOTE VERT ET JAUNE TERRE E Branchement du câble pilote Le câble de commande NOIR est conçu pour porte...

Page 16: ... afin d accroître le flux d eau dans l appareil Échangeur de chaleur sale Nettoyage et entretien utilisateur AVERTISSEMENT DÉCONNECTER L ALIMENTATION SECTEUR avant d effectuer toute opération de nettoyage ou d entretien Nettoyage général L aspect extérieur de l appareil peut être entretenu en essuyant ce dernier de temps à autre avec un chiffon humide pour éliminer les taches appliquer une solutio...

Page 17: ...convector is geoptimaliseerd om te werken in combinatie met de Dimplex serie warmtepompen en werkt ook goed op standaard olie of gasgestookte centrale verwarmingssystemen Een aantal van de functies van de kachel zijn aangegeven in Afb 1 a Esthetisch Voorpaneel b Thermostaat Ventilatorselectorpaneel c Metalen luchtuitlaatrooster d 1m lange kabel Om een optimale werking te garanderen moet u letten o...

Page 18: ...stand Alle bedrading moet zo worden aangesloten dat een beweging van het product niet leidt tot kortsluiting BELANGRIJK De kleur van de draden in dit netsnoer is op de volgende manier gecodeerd BRUIN ONDER SPANNING L BLUE NEUTRAAL N ZWART STUURDRAAD GROEN GEEL AARDE E Aansluiting stuurdraad De ZWARTE regelbedrading is ontwikkeld om een signaal over te brengen van sleuf of wandgemonteerde Dimplex p...

Page 19: ...pparaat te verhogen Vuile warmtewisselaar Reiniging en gebruikersonderhoud WAARSCHUWING SCHAKELNETVOEDING UITalvorens onderhoud uit te voeren en het apparaat te reinigen Algemene reiniging De buitenkant kan worden onderhouden door hem af en toe af te nemen met een vochtig doekje verwijder vlekken met een mild zeepsopje en wrijf het oppervlak na reiniging droog Interne reiniging en onderhoud Het ka...

Page 20: ......

Page 21: ...detaljer kan fås hos den forhandler hvor du har købt apparatet Der kan kun støttes ret på garantien ved forelæggelse af købskvittering og kun inden for garantiperioden Garantien bortfalder hvis apparatet er blevet beskadiget anvendt forkert eller i tilfælde af uautoriseret indgreb i apparatet SE Garanti För denna apparat gäller de för inköpslandet utgivna garantibestämmelserna På förfrågan kan det...

Page 22: ...e Assinatura do retalhista 6 Falha Defeito 7 Número de Contacto e Morada NL 1 Garantiebewijs 2 Garantieperiode in jaren 3 Model len 4 Aankoopdatum 5 Stempel Ondertekening detaillist 6 Fout Defect 7 Telefoonnummer Adres DK 1 Garantikort 2 Garantiperiode i år 3 Model ler 4 Købsdato 5 Detailhandlers stempel underskrift 6 Fejl defekt 7 Kontaktnummer adresse SE 1 Garantikort 2 Garantitid i år 3 Modell ...

Reviews: