background image

 

Quick Start Guide 

RXPW4 - 4 Zone Pilot Wire Central Controller 

Controls 

General 

Initial set up:  Setting the time and day 

Issue 1:   D1227-0106 

This guide is for quick reference only.  Refer to RXPW4 installation and operating instructions for further information 

1 - Time 

2 - Day of the week 

3 - Current mode 

4 - Zone status reference 

5 - Controller setup/override                                
buttons 

6 - Validation button 

7 - Holiday mode 

8 - Selector switch index mark 

9 - Mode selector switch 

Symbol

 

Function

 

 

Continuous comfort (all zones) 

AUTO 

Auto mode (heating runs to the preset program for each 
zone) 

 

Continuous set back (all zones) 

 

Continuous frost protection (all zones) 

 

Set the time 

 

Off (no heat output) 

 

Heater mode configuration 

PROG 

Set the daily programs 

Mode Selector Functions 

The RXPW4 controller allows control of multiple Dimplex heaters 
from a single point.  Heaters can be grouped together in “zones” 
and each zone configured with a different time program for each 
day of the week.  Up to 4 zones are available. 

Before the controller can be programmed, it is first necessary to set 
the current time and day of the week. 
1. 

Turn the mode selector switch to the   

position. 

2. 

Use the “+” and “-” buttons to cycle through the hours/
days of the week until the correct time/day is set.   

3. 

Press OK to confirm. 

Note

:  Typically 1 = Sunday, 2 = Monday, etc. 

Setting the daily program for each zone 

1. 

Turn the mode selector switch to the PROG position. 

2. 

Use the “+” and “-” buttons to select the zone you wish to 
programme (e.g. P=1).   

3. 

Press OK to select. 

4. 

Use the “+” or “-” buttons to set the program for each hour 
of day 1 (i.e. Sunday).   

5. 

“+”sets an hour of Comfort (on) and “-” sets an hour of 
Background (off).  The hours of the day are denoted across 
the bottom of the display. 

6. 

Press OK to confirm when the program has been set.  The 
programme for day 2, etc. can then be set in the same 
way.. 

7. 

To copy the program from one day to the next, hold down 
the OK button for 5 seconds. 

Setting the daily program for each zone (cont.) 

8. 

Once the daily programs have been set for Zone 1, repeat 
the process for Zones 2 - 4. 

9. 

To run the program, set the mode selector switch to the 

AUTO position. 

10. 

The status of each zone is indicated on the display (1 bar = 
background (off), 4 bars = Comfort (on). 

 

 

Temporarily over riding the the daily program 

When the programmer is in AUTO mode, the current setting for 
each zone can be temporarily over ridden (advanced). 

1. 

Press the OK button.  The bars above Z1 will flash. 

2. 

To change the status of zone 1 (e.g. from Comfort to Back-
ground), press the “+” or “-” button, followed by OK to 
confirm. 

3. 

Alternatively, to change the status of a different zone, press  
the OK button until the bars above the required zone flash 
and repeat the steps above to change the status. 

4. 

This will temporarily over ride the program until the next 
scheduled status change. 

Manual over ride (all zones) 

To permanently over ride the mode of all zones, turn the mode 
selector switch to one of the manual setting positions: 

 

 

COMFORT (ON) mode 
BACKGROUND (OFF) mode 
FROST PROTECTION mode 
STANDBY mode 

Please refer to the individual 
heater instructions to details of 
heater operation in each mode 

Glen Dimplex UK Ltd. Millbrook House, Hedge End, Southampton, SO30 2DF.  For further assistance please contact Dimplex customer services on 0870 727 0101

 