LIA 0608HWCF M - LIA 0911HWCF M
5
Installation
5.1 Indoor unit
The unit should always be installed indoors on a level, smooth
and horizontal surface. The indoor unit must be installed in a
way that allows maintenance work to be carried out from the
operator side without hindrance. This can be ensured by main-
taining a clearance of 1 m at the front. The space required (ap-
prox. 30 cm, see dimension drawing) for replacing the protec-
tive anode must be taken into consideration when determining
the required height of the installation room. It must be installed
in a room protected from frost and with short pipe runs.
CAUTION!
!!
In an unfilled state (domestic hot water cylinder without
water), the device has a tendency to tilt in the direction of the
hydraulic assembly. Do not lean on the rear of the unit!
Setup and installation must be performed by an authorised
specialist company.
Fig. 5.1: Indoor unit clearances
If the indoor unit is installed on an upper floor, the load-bearing
capacity of the ceiling should be checked. On account of the
acoustics, measures for isolating possible vibrations should
also be carefully planned in advance. Installation on floors
above wooden ceilings is not recommended.
The device should not be installed in rooms with high humidity
(e.g. shower rooms, wash rooms, etc.).
Furthermore, please note that the device has a tendency to tip
over when unfilled. Make sure that it is standing safely and re-
frain from leaning against the device or leaning objects against
the device.
CAUTION!
!!
The installation room must meet the requirements for the
minimum installation space (see cap. 5.3).
CAUTION!
!!
The device must be installed in a room with sufficient air
circulation.
CAUTION!
!!
The device must not be installed or operated near a naked
flame, gas-powered devices, electric heaters or any other
comparable source of ignition.
CAUTION!
!!
The device must not be installed in a room that is also used as
a workplace or workshop (risk of ignition due to flying sparks).
CAUTION!
!!
When installing the device, make sure that no ventilation
openings are blocked.
NOTE
ººººº
The heat pump is not intended for use above 2000 metres
(mean sea level).
50 mm
1000 mm