The product complies with the European Safety Standards EN13240 for Room heaters fired by solid fuel.

08/51568/0 - Issue 2

Please hand these instructions to the stove user when installation is complete. 

Leave the system ready for operation and instruct the user in the correct use of the 

appliance and operation of controls.

Installation should only be carried out by a suitably qualified installer that is registered 

with HETAS (UK) or with the Irish Nationwide Fireplace Organisation (INFO). 

Installation must comply with Building Regulations.

Langbrook 5kW (LBK5)

Summary of Contents for Langbrook 5kW

Page 1: ...tallation is complete Leave the system ready for operation and instruct the user in the correct use of the appliance and operation of controls Installation should only be carried out by a suitably qua...

Page 2: ...Wood kW 5 0 Solid Fuel Ancit kW 5 3 Efficiency Wood 77 0 Solid Fuel Ancit 82 5 CO Emission 13 O2 Wood 0 32 Solid Fuel Ancit 0 38 Flue Gas Temp Wood C 306 Solid Fuel Ancit C 249 Flue Gas Mass Flow Woo...

Page 3: ...T Min Wall height H 0mm 0 50mm 200mm Height of appliance 300mm or 1200mm from hearth whichever is greater 0mm 51 150mm 75mm 0 150mm 150 300mm 75mm 150mm 300mm No Minimum Requirement H MIN 150mm X X T...

Page 4: ...150 max Seal gap with fire proof lagging 150 max CLOSURE PLATE SEAL C D B A 10 8 9 7...

Page 5: ...possibility of personal injury Use protective clothing Fire Cement Glue Some types of fire cement glue are caustic and should not be allowed to come into contact with the skin Use suitable protective...

Page 6: ...be made from non combustible board sheet or tiles of minimum thickness12mm Fig 5 shows the minimum distances required 2 from the hearth edge to the sides of the stove In all cases allow an apron of at...

Page 7: ...and refuel Set air controls as required The stove is not suitable for overnight burning Notes on Wood Burning Wood burns best on a bed of ash and it is therefore only necessary to remove surplus ash...

Page 8: ...pprox b Chimney and or flue pipe restricted room ventilation restricted On installation these should have been checked but regular maintenance is necessary as conditions can change e g soot build up b...