EN-10 452163.66.06 · FD 9506
www.dimplex.de
English
LA 35TUR+
12 Device information
1
Type and order code
LA 35TUR+
2
Design
2.1
Model
Reversible with additional heat exchanger
2.2
Controller
External
2.3
Thermal energy metering
Integrated
2.4
Installation location / degree of protection according to EN 60529
Outdoor / IP24
2.5
Antifreeze condensate tray / heating water
Heated / yes
1
2.6
Performance levels
2
3
Operating limits
3.1
Heating water flow / return
°C
up to 60
2
± 2 / from 18
Cooling water flow
°C
/ +9
to +20
Air (heating)
°C
-25 to +40
Air (cooling)
°C
+10 to +45
4
Performance ratings / flow rate
3
4.1
Heating water flow rate /
internal pressure differential
A7/W35/30
m³/h / Pa
5.2 / 2900
A7/W45/38
m³/h / Pa
3.5 / 1400
Minimum heating water flow
A7/W55/45
m³/h / Pa
2.4 / 700
4.2
Heat output / COP
4
5
6
EN 255
EN 14511
at A-7 / W35
kW / ---
7
17.8 / 2.9
17.6 / 2.8
kW / ---
8
10.1 / 3.0
9.9 / 2.9
at A2 / W35
kW / ---
24.2 / 4.0
23.6 / 3.7
kW / ---
14.0 / 4.3
13.6 / 4.0
at A7 / W35
kW / ---
30.2 / 4.5
kW / ---
17.3 / 4.8
at A7 / W55
kW / ---
27.1 / 2.8
kW / ---
15.4 / 3.1
at A10 / W35
kW / ---
33.4 / 5.1
32.6 / 4.9
kW / ---
18.3 / 5.3
17.5 / 5.1
4.3
Minimum cooling water flow rate / internal pressure
differential
m³/h / Pa
5.2
9
/ 2900
4.4
Cooling capacity / COP
10
at A27 / W9
kW/---
27.3 / 3.6
at A27 / W7
kW / ---
15.0 / 4.2
at A27 / W18
kW / ---
32.0 / 3.9
kW / ---
19.1 / 4.9
at A35 / W9
kW/---
24.9 / 2.8
at A35 / W7
kW / ---
13.6 / 3.3
at A35 / W18
kW / ---
29.7 / 3.2
kW / ---
17.6 / 4.0
4.5
Sound power level energy / sound optimised
dB(A)
up to 72 / up to 70
4.6
Sound pressure level at a distance of 10 m
(air outlet side)
11
dB(A)
Up to 43
4.7
Flow rate of additional heat exchanger /
internal pressure differential
m³/h / Pa
2.5 / 9400
4.8
Air flow ((Controlling range EC fan)
m³/h
5000 - 15000
5
Dimensions, connections and weight
5.1
Device dimensions without connections
H x W x L mm
2100 x 1735 x 980 (750)
5.2
Device connections for heating system
Inches
1 1/2'' internal thread
5.3
Device connections for additional heat exchanger
(waste heat recovery)
Inches
1 1/4" external thread
5.4
Weight of the transportable unit(s) incl. packaging
kg
595
5.5
Refrigerant; total filling weight
type / kg
R417A / 21,3
5.6
Lubricant; total filling quantity
type / litres
Polyolester (POE) / 4.1