Fireplace Installation
Figure 2
Figure 3
nal/opening dimensions (Figure
1).
New Wall Construction
1. Mark the desired location on
the floor and store the fire-
place in a safe, dry and dust
free location.
2. Use studs to frame an open-
ing of 31 ¾ in. (807 mm) wide
x 22 ¾ in. (578 mm) high x 9
½ in. (241 mm) deep.
Option #1
- The power cord can
be lead from behind the trim and
along the wall to an outlet near
the fireplace.
Option #2
- A new outlet can be
installed inside the new frame
construction. Plug the unit into a
15 Amp, 120 Volt outlet.
!
NOTE 1:
A 15 Amp, 120 Volt
circuit is required. A dedicated
circuit is preferred but not es-
sential in all cases. A dedicated
circuit will be required if, after in-
stallation, the circuit breaker trips
or fuse blows on a regular basis
when the heater is operating. Ad-
ditional appliances on the same
circuit may exceed the current
rating of the circuit breaker.
Option #3
- Hardwire
1. Wire a dedicated, properly
fused circuit with 120 Volt,
15 Amp rating. Allow up to
8 ft. (2.4 m) of service cable
for connecting power supply
to junction box on fireplace
when installing after finishing
wall.
CAUTION:
Use two conduc-
tor, non-metallic sheath cable with
ground wire (three wires total) for
the incoming power supply on
fireplace inserts. Use appropriate
wire to meet local and national