8
www.dimplex.com
Bathroom Installation
This firebox must be protected by
a GFI receptacle or circuit. If a re
-
ceptacle is used it must be readily
accessible.
To prevent electrical shock this
unit is an electrical appliance
that is not watertight and must be
installed as to prevent water from
entering the unit. This unit must
be installed away from showers,
tubs, etc. Never locate fireplace
where it may fall into a bathtub or
other water containers.
Fireplace Installation
Wiring Diagram
M
M
RELAY BOARD
SWITCHBOARD
DISPLAY-CONTROL BOARD
FLAME LED LIGHT ASSEMBLY
THERMISTOR
N
~
MOTOR
L
FLICKER
120V / 12V
AC / DC
LOGSET ASSEMBLY
AC / DC ADAPTER
HEATER ASSEMBLY