Dimplex DF2624L Owner'S Manual Download Page 6

6  

www.dimplex.com

 Fireplace Installation 

 WARNING: 

To reduce the risk of 

fire, do not store or use gasoline or 

other flammable vapors or liquids in 

the vicinity of the heater.

 WARNING: 

Ensure the power 

cord is not installed so that it is 

pinched or against a sharp edge 

and ensure that the power cord is 

stored or secured to avoid tripping 

or snagging to reduce the risk 

of fire, electric shock or injury to 

persons.

 WARNING: 

Construction 

and electrical outlet wiring must 

comply with local building codes 

and other applicable regulations 

to reduce the risk of fire, electric 

shock and injury to persons.

 WARNING: 

Do not attempt 

to wire your own new outlets or 

circuits. To reduce the risk of fire, 

electric shock or injury to persons, 

always use a licensed electrician.

!

 

NOTE:

 A 15 Amp, 120 Volt 

alternating current (VAC) circuit 

is required. A dedicated circuit 

is preferred but not essential in 

all cases. A dedicated circuit will 

be required if, after installation, 

the circuit breaker trips or fuse 

blows on a regular basis when the 

heater is operating. Additional ap

-

pliances on the same circuit may 

exceed the current rating of the 

circuit breaker.

Glass Installation

(if applicable)
1.  Unpack the firebox and the 

front glass.

2. 

Remove the glass retaining 

bracket from one side of the 

firebox. (Figure 1)

3. 

Slide the glass into the glass 

support track on both the top 

and the bottom, until it is fully 

inserted.

4.  Replace the glass retaining 

bracket.

Figure 1

Summary of Contents for DF2624L

Page 1: ...s read this manual first before attempting to install or use this fireplace For your safety always comply with all warnings and safety instructions contained in this manual to prevent personal injury or property damage To view the full line of Dimplex products please visit www dimplex com ...

Page 2: ...emphasize CAUTION Procedures and techniques which if not carefully followed will result in damage to the equipment WARNING Procedures and techniques which if not carefully followed will expose the user to the risk of fire serious injury or death Welcome Congratulations 3 IMPORTANT INSTRUCTIONS 4 Fireplace Installation 6 Operation 9 Maintenance 12 Warranty 13 Replacement Parts 15 ...

Page 3: ... Manufacturer s Warranty Contact us at www dimplex com customer_support For Troubleshooting and Technical Support OR Toll Free 1 888 DIMPLEX 1 888 346 7539 Monday to Friday 8 00 a m to 4 30 p m EST In order to better serve you please have your model and serial number ready or register your product online before calling See above Please carefully read and save these instructions CAUTION Read all in...

Page 4: ... or damaged in any manner Return heater to authorized service facility for examination electrical or mechanical adjustment or repair IMPORTANT INSTRUCTIONS Do not use outdoors Never locate this heater where it may fall into a bathtub or other water container Do not run cord under carpeting Do not cover cord with throw rugs runners or the like Arrange cord away from traffic area and where it will n...

Page 5: ...ld new circuits or outlets be required Always use properly grounded fused and polarized outlets Disconnect all power supply before performing any cleaning maintenance or relocation of the heater When transporting or storing the heater and cord keep in a dry place free from excessive vibration and store so as to avoid damage WARNING Remote control contains a small battery Keep away from children If...

Page 6: ...mpt to wire your own new outlets or circuits To reduce the risk of fire electric shock or injury to persons always use a licensed electrician NOTE A 15 Amp 120 Volt alternating current VAC circuit is required A dedicated circuit is preferred but not essential in all cases A dedicated circuit will be required if after installation the circuit breaker trips or fuse blows on a regular basis when the ...

Page 7: ...ning dimensions for the fireplace are 27 0 in 686 mm wide x 23 in 587 mm high x 7 in 191 mm deep Figure 3 CAUTION Clearance for air circulation beneath the fireplace insert is provided by four felt feet Do not install the fireplace in sert directly on carpet or simi lar surfaces which may restrict air circulation CAUTION If installing the fireplace in a carpeted area place a one piece solid flat s...

Page 8: ...at is not watertight and must be installed as to prevent water from entering the unit This unit must be installed away from showers tubs etc Never locate fireplace where it may fall into a bathtub or other water containers Fireplace Installation Wiring Diagram M M RELAY BOARD SWITCHBOARD DISPLAY CONTROL BOARD FLAME LED LIGHT ASSEMBLY THERMISTOR N MOTOR L FLICKER 120V 12V AC DC LOGSET ASSEMBLY AC D...

Page 9: ...creen Display A Standby Turns the unit On and Off Activated by pressing the Standby button on the remote or the unit The unit will turn on with the same functions that it was set to when it was turned Off and the intake temperature will be indicated on the On Screen Display NOTE When any button is pressed the intake tempera ture will be displayed on the On Screen Display for 5 seconds B Flame Effe...

Page 10: ...the desired set temperature is reached the heater will turn off The heater will cycle on and off to maintain the desired set tem perature The default temperature setting is 72 F 22 C Adjusted by pressing the to decrease the setpoint and the to increase the setpoint on the remote The On Screen Display will in dicate the temperature setpoint as it is adjusted NOTE Holding the button down on the unit...

Page 11: ...e desired time is displayed The On Screen Display will display the different times as it is adjusted Once the timer has begun pressing the button will display the time remaining before the unit turns Off NOTE The Sleep Timer can be cancelled at any time by pressing the button repeat edly until the sleep timer displays nothing Resetting the Temperature Cutoff Switch Should the heater overheat an au...

Page 12: ...ith a clean dry cloth To remove fingerprints or other marks the front glass panel can be cleaned with a damp cloth The front glass panel should be completely dried with a lint free cloth to prevent water spots To prevent scratching do not use abrasive cleaners or spray liquids on the glass surface Compact Fireplace Surface Cleaning Use warm water only to clean painted surfaces of the Compact Firep...

Page 13: ...tested and inspected prior to shipment and subject to the provisions of this warranty Dimplex warrants such products to be free from defects in material and workmanship for a period of 12 months from the date of the first purchase of such product The limited 12 month warranty period also applies to any implied warranties that may exist under applicable law Some jurisdictions do not allow limitatio...

Page 14: ...abour or transportation costs Such costs shall be the purchaser s responsibility What Dimplex and its dealers and service agents are also not responsible for IN NO EVENT WILL DIMPLEX OR ITS DIRECTORS OFFICERS OR AGENTS BE LIABLE TO THE PURCHASER OR ANY THIRD PARTY WHETHER IN CONTRACT IN TORT OR ON ANY OTHER BASIS FOR ANY INDIRECT SPECIAL PUNITIVE EXEMPLARY CONSEQUENTIAL OR INCIDENTAL LOSS COST OR ...

Page 15: ...r 3001380100RP Cord Set 4100090204RP Flicker Rod 5902620100RP Partially Reflective Panel 5902580300RP Front Glass 5902570200RP Felt Feet Pads set of 4 8600140101RP Log Set Assembly 0439560400RP Display Control Board 3001350200RP Switchboard 3001370100RP Relay Board 3001360100RP AC DC Adapter 2100250100RP LED Light Assembly 2 LED s 3001390100RP LED Light Assembly 3 LED s 3001390200RP Remote Control...

Reviews: