www.gdts.one
451903.66.07 · FD 9908
EN-9
BWP 20A
English
11 Technical Data
Device information for hot water heat pumps
1
Type and order code
BWP 20A
2
Design
Without internal heat exchanger
2.1
Nominal cylinder volume
l
200
2.2
Cylinder material
Enamelled steel according to DIN 4753
2.3
Nominal cylinder pressure
bar
10
3
Model
3.1
Dimensions height (max.) x cross-section (max.)
mm
1700 x 550
3.2
Weight (empty)
kg
Approx 96
3.3
Electrical connection
(plug-in - lead length approx. 2.7 m)
1/N/PE ~ 230V, 50Hz
3.4
Fuse
A
16
3.5
Refrigerant / total filling weight
- / kg
R134a / 1.0
3.6
GWP value / CO
2
equivalent
--- / t
1430 / 1
3.7
Refrigeration circuit hermetically sealed
yes
4
Performance data
4.1
Range of operating temperatures
±1,5 K
)
°C
15 to 35
4.2
Selectable water temperature (heat pump operation
±1.5 K
) °C
23 to 60
4.3
Heating-up period from 15°C to 45°C at (L20 / F50)
h
7.2
4.4
Power consumption supplementary electrical heating
W
1500
4.5
Mean power consumption
1
at 45 °C
W
1. Heating-up of nominal volume from 15 C to 45 C at L20/F50 = Exhaust air temperature 20 C and exhaust air humidity 50%
256
4.6
at 45 °C
W
970
4.7
COP
(t)
according to EN 255 at 45 °C
-
3.68
4.8
Sound pressure level
2
dB(A)
2. At a distance of 1m (free-standing installation or installation without exhaust air duct or 90° pipe bends on outlet side) The specified sound pressure level represents the free sound
area level. The measured value can be up to 16 dB(A) higher, depending on the installation location and conditions within the building.
44.5
4.9
Air flow (with air duct)
m
3
/h
140
4.10 External compression
Pa
110
4.11 Maximum air duct connection length (total)
m
10
4.12 Diameter of the air duct connection
mm
125
4.13 Hot water connection - outlet
External thread
R3/4“
4.14 Cold water connection - inflow
External thread
R3/4“
Summary of Contents for BWP 20A
Page 2: ......
Page 14: ...DE 12 451903 66 07 FD 9908 www gdts one Deutsch BWP 20A...
Page 24: ...EN 10 451903 66 07 FD 9908 www gdts one English BWP 20A...
Page 34: ...FR 10 451903 66 07 FD 9908 www gdts one Fran ais BWP 20A...
Page 41: ...www gdts one 451903 66 07 FD 9908 A VII BWP 20A Anhang Appendix Annexes...
Page 42: ...A VIII 451903 66 07 FD 9908 www gdts one Anhang Appendix Annexes BWP 20A...
Page 43: ...www gdts one 451903 66 07 FD 9908 A IX BWP 20A Anhang Appendix Annexes...