Domestic ventilation unit M Flex Air (Plus)
English
Filter time
The filter signal provides a filter maintenance reminder as a text
notification and flashing of the display after the set interval time
has elapsed or a predefined maximum level of soiling has been
reached.
The filter time can be set in a range of 2 - 18 months. The fac-
tory setting is 6 months.
Reset active filter signal:
After the filter maintenance the signal is acknowledged / reset
using the OK key and the filter time is then restarted.
Reset without filter signal:
The interval time can be restarted in the user menu under 30 -
Parameter / 31 - Status signal by pressing the OK key in the dis-
play 315 - Filter signal.
HINWEIS
ºº
º
ºº
º
NOTE
In the event of a power failure or if the ventilation unit is
switched off, the filter time is not reset.
Bypass
The bypass directs the outside air past the heat exchanger and
directly into the building. Heat recovery is deactivated. In sum-
mer, this function can be used to direct cool outside air (e.g. at
night) into the rooms.
Sensor
The control sensitivity of the connected air quality sensors (op-
tional) can be changed in a range of -10…0…+10.
The sensitivity can be increased, e.g. for a duct sensor
(+1…+10), or decreased e.g. for a room sensor
(-1…-10). The factory setting is 0.
Operating and status information
A wide range of information can be shown relating to the status
and operation of the ventilation unit. It is not possible to change
settings in this menu.
The information shown in the menu items described below can
help the installation engineer, after-sales service or Service Hot-
line staff to perform diagnostics in the event of a fault. Much of
this information will only be understood by trained engineers.
Status signal
Displays the current operating mode, bypass flap status, fire-
place safety function and temperatures
Air flow
Displays the configured supply air and exhaust air volume flows
for the relevant operating modes speed 1, 2, 3 and Automatic
Error signal
Displays the currently active error message (active error) with
details of the date, time and operating mode.
Displays the 8 most recent error messages (error history, entry
1…8), each with details of the date, time and operating mode at
the time the error occurred.
8.4 Service menu
Basic settings for operating the ventilation system are made in
the service menu. The parameter settings in the service menu
adapt operation of the unit to individual requirements of the rel-
evant building. The settings must be carried out by an engineer
during commissioning and usually should not need to be
changed after that.
Access: Press the and
OK
keys simultaneously for
5 sec
Fig. 8.5:Service menu
The service menu is indicated with the
symbol in the top
left of the display.
HINWEIS
ºº
º
ºº
º
NOTE
Settings in the service menu have a major impact on the oper-
ation of the system and should only be carried out by a quali-
fied engineer. Improper or incorrect settings can reduce the
efficiency of the system and result in malfunctions!
Navigation in the menu structure
takes place within the level
using the and keys. The required menu item is selected
using the
OK
key. To exit a level, press the key for longer.
The
settings are changed
in a similar way using the
and
keys. Press the OK key to save the desired value. To
exit the menu item without saving, press the key for 1 sec.
HINWEIS
ºº
º
ºº
º
NOTE
If no settings are made for 180 seconds, the user is returned
to the basic display.
The ventilation unit is designed for use in different regions.
Minor variations from the following menu description are not
relevant for general operation.
5 sec.
+
OK
d
Bedienermenü
80 Modbus
d
Bedienermenü
70 Special func.
d
Bedienermenü
60 Information
d
Bedienermenü
50 Outputs
d
Bedienermenü
40 Inputs
d
Bedienermenü
30 Parameter
d
Bedienermenü
20 Settings
#
Service menu