background image

Dimension One Spas - Aquatic Fitness System Owner’s Manual 

 

i

 

Your Product Information 

Please gather the following important information about your Dimension One Aquatic Fitness System 
(AFS) and register your product online at 

www.D1.com

. Registering your product establishes your 

warranty, protects your product and helps us develop new and better products. 

 
 

My Aquatic Fitness System 
 

Model Name: 

Serial 

Number:

 

 

 

Date Purchased: 

Date 

Installed:

 

 

 

Gallons/Liters:  

 

 

Notes:  

 

 

 

 

 

 

 

 

 
 
 
Dealer Information: 
 

Dealer’s Name:

 

 

Address:

 

 

City:

State, Zip:

 

 

Telephone:

Fax:

 

 

 

 
 
 
 
 

Summary of Contents for Aquatic Fitness System

Page 1: ...quatic Fitness System AFS and register your product online at www D1 com Registering your product establishes your warranty protects your product and helps us develop new and better products My Aquatic Fitness System Model Name Serial Number Date Purchased Date Installed Gallons Liters Notes Dealer Information Dealer s Name Address City State Zip Telephone Fax ...

Page 2: ...SWIM TETHER 17 USING THE SWIM KICK BAR 18 USING THE SWIM JETS 18 OPTIONAL HYDROSPORT ROWING SYSTEM 19 INSTALLING THE ROWING SYSTEM 19 ROWING FOR THE FIRST TIME 20 CONNECTING THE HYDROSPORT BODY BELT 21 CONNECTING THE HYDROSPORT D HANDLES 21 CONNECTING THE HYDROSPORT BAR STRAPS 21 HYDROSPORT EXERCISE BARS 22 INSTALLING THE STATIONARY EXERCISE BARS 22 HYDROSPORT AQUATIC FITNESS BAR 22 INSTALLING THE...

Page 3: ...r without lowering the water level below the light housing cover To Reduce the Risk of Injury The water in the Aquatic Fitness System should never exceed 104 F 40 C Water temperatures between 100 F 38 C and 104 F 40 C are considered safe for a healthy adult Lower water temperatures are recommended for young children and when Aquatic Fitness System use exceeds 10 minutes To Reduce the Risk of Injur...

Page 4: ... DU CORPS PUISSENT TRES ASPIRÉS NE PAS UTILISER UNE CUVE DE RELAXATION SI LES GRILLES DE PRISE D ASPIRATION NE SONT PAS TOUTES EN PLACE People using medications and or having adverse medical history should consult a physician before using an Aquatic Fitness System or hot tub AVERTISSEMENT LES PERSONNES QUI PRENNENT DES MÉDICAMENTS OU ONT DES PROBLÈMES DE SANTÉ DEVRAIENT CONSULTER UN MÉDECIN AVANT ...

Page 5: ... DE DROGUE AUGMENTE CONSIDÈRABLEMENT LES RISQUES D HYPERTHERMIE MORTELLE DANS UNE CUVE DE RELAXATION SAVE THESE INSTRUCTIONS Hyperthermia Prolonged immersion in hot water may induce hyperthermia Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98 6 F 37 C The symptoms of hyperthermia include dizziness drowsiness leth...

Page 6: ...y AFS has a warning sign that outlines safety precautions Read and familiarize yourself with all warnings listed on this sign Make the sign visible and accessible to all AFS users Replacement signs may be obtained from Dimension One Spas 2611 Business Park Drive Vista CA 92081 ...

Page 7: ... After turning off the GFCI check for a blank control panel screen which means the power is off To turn power back on move the switch to the ON position If you have questions about the location or operation of your GFCI ask your dealer for clarification DO NOT use your system unless you understand the operation of the GFCI 1 Locate the equipment compartment beneath the steps of the AFS Have your d...

Page 8: ... system until the water level reaches the center of the tile line 10 After filling the system return the filter to its basket After the filter is in place turn on the GFCI circuit breaker The Display Window of the Pool will show the current water temperature NEVER run your spa s pumps without the filters in place This can cause damage to the pumps 11 Prime the pumps by pushing the JETS 1 button on...

Page 9: ...r more details pg 15 The Display Window does not allow you to set the temperature above 104 F 40 C However if the water temperature exceeds 104 F 40 C the display will show the actual temperature Never get in water if the temperature exceeds 104 F 40 C 13 While heating the spa inspect the pump unions and plumbing fittings for leaks When you have finished the inspection you can reinstall the equipm...

Page 10: ... A third press turns the pump off unless the pump has been automatically activated during a heating cycle in which case a third press returns the pump to Low Speed for heating A built in timer automatically shuts the pump off after 20 minutes of operation The Jets 1 Indicator light beside the button will glow while the pump is running Pump 1 powers the Swim Jets and or HydroTherapy Jets The divert...

Page 11: ...s run at high speed If you have the maximum electrical service then you can continue to heat your water while running the pumps at high speed Ask your dealer if you have questions about your electrical service Light Button Push the LIGHT Button once to turn on the spa light in Color Change mode In Color Change mode the light will continuously cycle through Red Green Blue White and Magenta To switc...

Page 12: ...ater is 2 F 1 C above your set temperature In Standard Mode heating the water remains independent of the filter cycles In economy mode the water only heats when the filter runs during a normal filtration cycle After entering the filter programming mode press the WARMER up button or the COOLER down button until you see F1 F2 F3 F4 F5 or F6 F1 2 hours of filtration 2 times a day Standard F2 2 hours ...

Page 13: ...ure display flashes while you remain in this mode If the system was heating when you put it in lockout mode the heater immediately turns off and the pumps run for thirty seconds then turn off L2 Panel Lockout To prevent unauthorized use of you system use the L2 mode to lock the control panel Start the programming sequence by pressing and holding both the warmer and cooler buttons for three 3 secon...

Page 14: ...tton The jet pump activates The jet indicator light glows A swirl icon appears in the upper left corner of the display window Its swirl speed indicates the pump s speed Pushing the JETS button once starts the pump on low speed Pushing it a second time turns on high speed Pushing it a third time turns the pump off A built in timer will automatically shut the pump off after 30 minutes You can reprog...

Page 15: ...lly Program Button Push the PROGRAM Button to begin the process of programming or reprogramming the spa See Programming the Spa Functions for details pg 15 Heat Status Light The Heat Status Light is illuminated whenever the heater is on Additionally a heat icon will also be displayed in the upper left corner of the Digital Display Window Dimension One Spas ICON Logo Push the Dimension One ICON but...

Page 16: ...act your local Authorized Dimension One Spas Dealer or authorized service center If you have flashing lights but the Digital Display Window shows the current water temperature you have a water flow problem You will need to check the water level and or clean the filters The flashing lights should stop once the problem is fixed If the problem persists reset the power to the spa by resetting the GFCI...

Page 17: ...tons to set the minutes the press Light to move to the AM PM setting Use the Up or Down buttons to select AM or PM Then press the Program button to move on to the next step Filter Cycle Start Time When you press the Program button the 2nd time the Filter Icon appears in the Display Window to indicate that you are setting the Filter Cycle Start Time Use the Up and Down buttons and the Light button ...

Page 18: ...w long the pump will run when a Jets Button is pushed before shutting off automatically The pre set factory default is 60 minutes Temperature Units ºF or ºC Pressing the Program button the sixth time brings you to the Temperature Unit selection Use the UP or DOWN Buttons to choose Fahrenheit ºF or Celsius ºC The factory default setting is Fahrenheit Press the Program Button a seventh time to finis...

Page 19: ...nd your waist using a quick release buckle and adjusts from the back Swim Tether Mounts are located at either end of the AFS see picture at left Place the pole in the mount strap on the adjustable belt and adjust the cord length If speed is your goal the Swim Tether allows you to swim as fast as you want and remain stationary Do not allow your Tensor Cords to remain in direct sunlight for extended...

Page 20: ... tile markers on the side front and bottom of the spa to properly position yourself in the swim lane You can also use the swim jets for resistance to while walking or jogging in place Using the Diverter Valve The diverter valve at the filter end of the AFS controls water movement from Pump 1 Turn the valve to direct water flow either in the direction of the hydrotherapy or swim jets Adjusting Air ...

Page 21: ...into an OptiMount on the wall on each side of the rowing seat Be sure to remove the plastic insert from the center of the OptiMount Use the OptiMounts identified by 2 in the 1 2 3 picture 3 Choose a tensor cord for your rowing exercise Snap a clip from one end of the rower to a Butterfly Top Snap the other end of the cord to the rower As a starting point use the red cords Change colors to adjust r...

Page 22: ...age The rowers are designed with four separate connection rings allowing you the option of multiple Tensor Cords that offer a wide range of exercises A variety of OptiMount locations allow for installation of additional Butterfly Tops for more cords The addition of various lengths of cord provide many ways to customize your exercise Rowing for the First Time Using the Rower Double check the HydroS...

Page 23: ...wrist or ankle and adjust the cuff to fit you comfortably Be sure it fits firmly If the cuff comes loose during your exercise you or your partner could be injured Snap a HydroSport tensor cord into the D rings on the cuff and connect the other end of the cord to a Butterfly Top in an OptiMount Connecting the HydroSport D handles Snap a HydroSport tensor cord into the D Ring of a D handle and conne...

Page 24: ...s Push the Butterfly Top screw through the hole in the end of the bar and screw it into the OptiMount Repeat for the other end of the bar If two bars connect to the same OptiMount line up the holes on the bars insert the Butterfly Top and connect to the OptiMount HydroSport Aquatic Fitness Bar Installing the Aquatic Fitness Bar Snap one end of the tensor cord to the Butterfly Top The other end of ...

Page 25: ...e basket line up with the securing tabs Pull the basket assembly straight up to remove it Remove the filter below the basket by twisting it 1 4 turn counterclockwise to its stop Lift the filter out of its canister Clean the filter with a high pressure garden hose Every other cleaning soak the filter in filter cleaning solution and rinse it thoroughly Reinstall the filter by reversing the removal p...

Page 26: ...e cabinet clean periodically with any non abrasive household cleaner Should the TimberLite cabinet become stained use the 3M Graffiti Remover System to remove the stain Special Cold Weather Instructions Dimension One Spas design allows for year round use The insulation allows for energy efficiency and protection of the plumbing and equipment when the system remains operational The system has a Sma...

Page 27: ...aged Make sure all the fittings that loosened are re tightened Replace all jet fittings pump drain plugs hose bib drains and bleeder valves Fill the system with water in the normal way Turn the power back on Run the jets on high speed for about 15 minutes Drain the water Put the filter s back in Refill the system and treat chemically as one would after a normal water change For more information ab...

Page 28: ...another cycle If desired reprogram automatic pump timer for a longer duration Pump shuts down unexpectedly while in use 2 Motor over heated and automatic protective device has shut down pump s 2 If pump s will not restart when JETS pad is pushed call for service 1 Check water level 2 Clean filter If problem persists 1 Turn off power 2 Restart the system If problem persists 3 flashing lights appear...

Page 29: ... or pressure switch has malfunctioned Check for proper water level ensure pump is primed and or check for clogged filter Pressure switch may need to be adjusted Call the dealer for service Pressure switch problem Pressure switch is closed while pump is deactivated Pressure switch may need to be adjusted Call your dealer for service Cool condition If the water temperature drops 20 F 11 C below the ...

Page 30: ...ure condition Do not enter the spa water The water temperature is above acceptable limits Water temperature has reached 110 F 43 C Call your dealer for service High limit condition Do not enter the spa water The water temperature has reached 118 F 47 8 C The entire system is disabled Call your dealer for service ...

Page 31: ...ble levels in which case call your dealer for service 3 Flashing Lights AND OH on LED Digital Display Window High Limit Condition Do not enter spa water The water temperature is above acceptable limits The water temperature has reached 118 F 47 8 C The system will shut down Call your dealer for service 3 Flashing Lights System Error 1 Check the water level 2 Clean the filters 3 If the problem pers...

Reviews: