30
FI-521 User Manual
NOTE: If AD.FROM = COM2, COM2 and OUT2 will be disabled.
PEAK
DISPLAY
MAX
MAX
Select what is displayed in Peak
mode
MAX= Max. Force value
MIN= Min. Force value
PEAK= current captured peak
value
VALLEY= current captured
valley value
MIN
PEAK
VALLEY
OTHER
NLD.RNG
1-255
10
1-255=the range of weight is 1-
255d. When current weight is
less than this value, the scale
can be regarded as empty, or
the load on scale is removed.
It must be bigger than
(CONFI.MOTION).
CMD.SRC
NONE
COM.1
Source of the executed
command selection
(1)NONE=no any command will
be executed
COM.1
(2)COM.1= command from
COM1 will be executed
COM.2
(3)COM.2= command from
COM2 will be executed
COM1-2
(4)COM.1.2= command from
COM1 or COM2 will be
executed
A.OFF.T
0-255
0
Auto off time
0=not auto power off
1-255=auto power off after 1-
255 minutes. In this period, no
operation or no weight change
A.OFF.MD
OFF
OFF
Auto off mode
(1)OFF=turn off indicator
DSP.TIM
(2)DSP.TIM= display time
DSP.DAT
(3)DSP.DAT=display date
AC.TIME
(4)AC.TIME=turn off when only
battery is used. Display time
when AC adaptor is used
AC.DATE
(5)AC.DATE=turn off when only
battery is used. Display date
when AC adaptor is used
LED.BRT
BRT1-2-
3-4-5
BRT4
LED brightness level set
BRT1-BRT5 =low - high
ind.ID 000000-
999999
123456
Indicator ID number: 000000-
999999
USER
SubMenu1
SubMenu2
Option
Default
Parameter Description
Comment