Page 1: ...1 Phase AC EV Portable Charger Quick Installation Guide DK 1P16 A 050 Rev 1 0...

Page 2: ...breaker 1 2 Maintenance It is recommended that routine safety inspection on the charger to be conducted at least once a week Please do not attempt to disassemble repair or modify the charger by yourse...

Page 3: ...find any please contact the supplier in time In case of rain or thunder please charge with care DO not charge if the power outlet is damaged rusted cracked or loosely connected Before charging make s...

Page 4: ...tact metal conductor to prevent electric shock accident Lightning proof Flame resistance Overvoltage protection Waterproof IP55 Overcurrent protection Leakage protection Overheat protection IEC 62196...

Page 5: ...er meets IEC 61851 control principle Long durability Charging adapter at no load plug in pull out 10000 times High impact of external force resistance 3 Package Content 1 x AC Portable Charger 1 x QIG...

Page 6: ...phase 1 Phase Protection Over voltage protection Under voltage protection Over current protection Over temperature protection Residual current protection RCD Type A Terminal temperature rise 50K LCD D...

Page 7: ...y standard UL94 V 0 IP Protection IP55 Mechanical spec Insertion life cycles 10000 times 5 Led Screen Description 1 Temperatur for the Control Box 5 Charging Time 2 Transpertised Energy 6 Charging Vol...

Page 8: ...e charger to adjust the max current rating to set an upper limitation with following steps 1 Power on the device with Schuko AC connected It would boot up and wait for connection by showing two green...

Page 9: ...ice even after power off While waiting for charging POWER LED and CHARGER LED light up green at the same time you can press A to adjust the current During normal charging POWER LED is always on and CH...

Page 10: ...ing for charging 3 On Flash 1s Off Normal working mode 4 On Off Off Charge complete 5 On Off Fault 0 5s on 0 5s off 1 time Circuit Board Overheat protection 6 On Off Fault 0 5s on 0 5s off 2 time Unde...

Page 11: ...g the AC Schuko plug to the wall socket 3 Make sure that the power outlet complies with national standards and that the socket can support max 16A For long term usage with Schuko connection it is reco...

Page 12: ...cle 3 Cover the charging plug with its protective cover Hereby Assmann Electronic GmbH declares that the Declaration of Conformity is part of the shipping content If the Declaration of Conformity is m...