background image

OFF 

 10/100M speed 

Reserve polarity protection 

Present 

Overload current protection 

Present 

Power Supply 

Redundant Dual Power Input 
12VDC-56VDC or 18VAC-36VAC 

Power Consumption 

2.76W@48 VDC full load 

Removable Terminal Block 

Provide 2 Redundant power, 4 Pin 
Wire range: 0.34mm^2 to 2.5mm^2 
Solid wire (AWG): 12-24/14-22 
Stranded wire(AWG): 12-24/14-22 
Torque: 5lb-In/0.5Nm/0.56Nm 
Wire Strip length: 7-8mm 

 

Operating Temperature 

-40°C to 75°C  

Operating Humidity 

5% to 95% (Non-condensing) 

Storage Temperature 

-40°C to 85°C 

MTBF (mean time between 
failure) 

>500,000 hrs (MIL-HDBK-217F) at 25°C 

Housing 

Rugged Aluminum, IP30 protection 

Case Dimension (L x W x D) 

103.5 x 32 x 81.5 mm (L x W x D) 

Installation mounting  

DIN Rail and Wall Mount options 
included  

 

 

 

Summary of Contents for DN-651107

Page 1: ...nd VDC power input It is suitable for heavy usage environments such as hazardous environments or central control areas where a reliable device is critical It is an ideal solution for Industrial Automation IP surveillance traffic monitoring and a wide range of applications It has been rigorously tested for your security transportation and telco applications ...

Page 2: ...ise Immunity Extended environment specification 40 C to 75 C Installation package This unit can be din rail mounted or wall mounted Din rail brackets and wall mounted brackets are included Package Content 1x Main unit 1x User Manual 2x Wall Mount Bracket 1x DIN Rail Bracket 1x 4 pin Terminal Block 4x Screws Wall mount bracket x 2 Philips Head Screw x 4 Din Rail Bracket x 1 4 pin Terminal Block x 1...

Page 3: ...tral wire to the ground screw V1 is for power input one connection V2 is for power input two connection Power connecting procedure STEP 1 Take out 4 pin terminal block located in the included mounting kit package STEP 2 Connect power wires to V1 or V2 with corresponding polarity Connect the grounding wire to the ground screw STEP 3 Plug into terminal block socket shown above Polarity needs to matc...

Page 4: ... P1 is NOT connected PW2 Green ON when P2 P2 is connected OFF P2 P2 is NOT connected Link Green ON Link port is detected OFF Link port is not detected Flashing Link port is active SPD Amber ON TX port 1000M speed is detected OFF TX port 100M speed is detected ...

Page 5: ...ntrol IEEE 802 3x Flow Control and Back Pressure Jumbo Frame 9KB MAC address Table Size 8K Packet Buffer Size 1M Network Connector 5xRJ 45 10 100 1000BaseT X auto negotiation Auto MDI MDI X function Full Half duplex Network Cable UTP STP above Cat 5e Cable EIA TIA 568 10 ohm 100m Protocol CSMA CD LED PW1 Green ON Power is detected PW2 Green ON Power is detected TX RJ 45 port LNK Green TX port is d...

Page 6: ...ge 0 34mm 2 to 2 5mm 2 Solid wire AWG 12 24 14 22 Stranded wire AWG 12 24 14 22 Torque 5lb In 0 5Nm 0 56Nm Wire Strip length 7 8mm Operating Temperature 40 C to 75 C Operating Humidity 5 to 95 Non condensing Storage Temperature 40 C to 85 C MTBF mean time between failure 500 000 hrs MIL HDBK 217F at 25 C Housing Rugged Aluminum IP30 protection Case Dimension L x W x D 103 5 x 32 x 81 5 mm L x W x ...

Page 7: ...ired to take appropriate measures Hereby Assmann Electronic GmbH declares that the Declaration of Conformity is part of the shipping content If the Declaration of Conformity is missing you can request it by post under the below mentioned manufacturer address www assmann com Assmann Electronic GmbH Auf dem Schüffel 3 58513 Lüdenscheid Germany ...