DGM INSTALLATION AND MAINTENANCE MANUAL
16
700135-0000 Rev. O
2.12.3.2 P1
This connector must be plugged into P0 of the main board of the DGM. This
connector is polarized for proper insertion.
2.13 32 ZONE EOL
2.13.1 GENERAL
Each 32 Zone EOL card may be switch selected for zone groups of 32. A DGM-32 is
supplied with one 32 Zone EOL card (expandable to two). A DGM-64 is supplied
with two 32 Zone EOL cards.
The 32 Zone EOL card provides lightning/transient protection for each zone input.
2.13.2 INSTALLATION
STEP 1: Place a 32 Zone EOL board over the mounting holes and start the top left
and top right mounting screws.
STEP 2: Start the lower left and lower right screws and tighten all mounting screws.
STEP 3: Connect the ribbon cable plug from P0 of the main board or from P1 of the
previous 32 Zone EOL board to P1 of the 32 Zone EOL board being installed.
2.13.3 WIRING
2.13.3.1 BS1 - BS8
Barrier strips BS1 - BS8 contain terminals for the connection of field wiring to the
Class B zone initiating inputs. Zone numbering for the 32 Zone EOL cards is
supplied with the system. For additional boards, terminal designations increase by
32 for each expansion board.
2.13.3.2 J1
This connector must be plugged into P0 of the main board of the DGM. This
connector is polarized for proper insertion.
2.14 32 CHARACTER LCD DISPLAY
The 32 CHARACTER liquid crystal display (LCD) and keypad are standard with the
DGM-32-M32-RLY and DGM-32-M32-RLY-RF units. Only one 32 Character LCD
display may be used for each DGM.
2.14.1 WIRING
2.14.1.1 P1
This connector must be plugged into P3 of the main board of the DGM. This
connector is polarized for proper insertion.