700135-0000 Rev. O
9
2 INSTALLATION
2.1 HANDLING
2.1.1 PRECAUTIONS
CAUTION!: Do not touch circuitry during installation. Static discharge may damage
components.
2.2 UNPACKING AND INSPECTION
Before opening, inspect the shipping container for unusual damage. Then, carefully
unpack the unit and inspect it for scratches, dents, and loose internal components. If
your inspection reveals any physical damage, retain the packing material and
contact the shipping carrier immediately. Each unit has been thoroughly inspected
prior to shipment. When returning a damaged panel, retain the tie wraps for the
inner door hinge and latch. Failure to tie wrap the inner door during shipping may
result in additional damage.
NOTE: Keep unit in shipping container until ready to mount.
2.3 CABINET MOUNTING
2.3.1 SITE PREPARATION
The installation area should be: well lit, clean, easily accessible and free from
extremes of temperature and humidity. Please refer to
Section
1.4.7,
TEMPERATURE AND HUMIDITY
for the maximum operating conditions.
2.3.2 DISASSEMBLY PROCEDURE
STEP 1: Retrieve the unit from its shipping container and place the back of the unit
down on a flat surface.
STEP 2: Using a CAT-
1 key, (two are supplied in an envelope marked “KEYS”),
open the hinged door.
STEP 3: Open the inner door and unplug any connectors and wire harnesses that
connect the equipment on the door to the equipment inside the cabinet. Wires and
ribbon cables should be disconnected on the cabinet side. When the inner door is in
the open position, lift it to remove it. Place equipment that has been removed in a
safe location.
STEP 4: Remove the four mounting nuts that secure the back plate to the enclosure.
Remove the back plate from the enclosure.