background image

Section Four - Tutorial 

A Guided Example

Suppose you wanted to create your own HyperModel™ that incorporated the sweet tones of a vintage Tweed with an
American 2x12 cabinet, and the ripping distortion of a Rectified Amp with a British 4x12 cabinet. Let’s also suppose
that we want to be able to toggle between an acoustic guitar simulation and this new HyperModel™ in a Preset which
gave your single coil pickup a humbucker sound, used no Compression, had a Noise Gate that opens quickly, a subtle
Chorus effect, no Delay, and a little bit of a Hall reverb.The following steps will guide you through the procedure for
creating just such a Preset in the GNX1.

Choose a Preset

The first step in creating a Preset is selecting your starting point.You can start with any Preset, but for this example
let’s start with Preset 40. Use the Footswitches or the Data Up/Down buttons to select Preset 40.

Create a HyperModel™

For this example, we are going to use a vintage Tweed amp with an American 2x12 Cabinet, and warp it with a
Recitified Amp using a British 4x12 cabinet. After selecting Preset 40, the GNX1 will be ready to select the Amp Models
(indicated by the yellow Status button LED).

Select the Green Channel Amp and Cabinet

The LEDs next to the Number 1 and Number 2 knobs are lit green indicating that these two knobs will select the
Amp and Cabinet types for the Green Channel.To assign the vintage Tweed amp to the Green Channel, rotate the
Number 1 Knob until the Display reads 

TWEED

(Tweed).Then rotate the Number 2 Knob until the Display

reads 

AM2X12

(American 2x12).

Select the Red Channel Amp and Cabinet

The LEDs next to the Number 4 and Number 5 knobs are lit red indicating that these two knobs will select the
Amp and Cabinet types for the Red Channel.To assign the Rectified amp to the Red Channel, rotate the Number
4 Knob 
until the Display reads 

RECTIF

(Rectified).Then rotate the Number 5 Knob until the Display reads

BR4X12

(British 4x12).

25

S

ECTION

F

OUR

- T

UTORIAL

Summary of Contents for GNX1

Page 1: ...GENETX GUITAR PROCESSOR TM USER S GUIDE...

Page 2: ...g on the available power source at installation If the attachment plug needs to be changed refer servicing to qualified service personnel who should refer to the table below The green yellow wire shal...

Page 3: ...roduct is returned to Digitech WITH RETURN AUTHORIZATION where all parts and labor will be covered up to a period of one year A Return Authorization number may be obtained from Digitech by telephone T...

Page 4: ......

Page 5: ...r 21 Triggered Phaser 22 Tremolo 22 Panner 22 Vibrato 22 Rotary 22 AutoYa 23 YaYa 23 SynthTalk 23 Envelope Filter 23 Detuner 23 Pitch Shifting 24 Delay 24 Reverb 24 Section Four Tutorial A Guided Exam...

Page 6: ......

Page 7: ...programming as simple as turning a knob However when you have to stop playing because your fingers are bleeding we feel that your recovery time would be well spent by reading through this User s Guide...

Page 8: ...return the GNX1 to Performance mode Select Preset The GNX1 comes with 48 pre programmed Factory Presets and 48 User Presets From the factory the User Presets are exact duplicates of the Factory Preset...

Page 9: ...ent 5 Parameter Knobs In performance mode these 5 knobs are used to select Amp Models Speaker Cabinets and Warp the Models In Green or Red mode they adjust the Amp Gain EQ and Level for the Green and...

Page 10: ...in Utility mode D Store The Store button is used to save your custom edits to the user Presets The function of this button changes to select Pattern in Rhythm mode E Utility The Utility button provide...

Page 11: ...ut for stereo applications Connect from this output to the input of a second amplifier or the right input of a stereo power amp 6 Output Level This knob controls the overall volume level of the GNX1 7...

Page 12: ...ystem Setup of the Utility menu See page 34 for more information on selecting the Target System Setup Mono Operation Connect your guitar to the input of the GNX1 Connect the Left output of the GNX1 to...

Page 13: ...EQ response on most amps this would be 0 or 5 on the tone con trols Turn the Output Level of the GNX1 up to achieve the desired volume level About the GNX1 The Presets Presets are named and numbered l...

Page 14: ...bank needs to be selected in order to activate the Bank If no Preset selection is made within 5 seconds The GNX1 will return to the last Bank and Preset that had been active FX Mode FX mode is anothe...

Page 15: ...otswitch representing the currently active Preset the 1 3 footswitch that is lit or press Footswitch 1 and 2 simultaneously To bypass the GNX1 while in FX Mode press the 1 and 2 Footswitches simultane...

Page 16: ...o plug Set the level of the player to a desired listening level 2 Cue up to the passage you want to record and hit pause on the Tape CD or MP3 player 3 Press and hold the number 2 and 3 Footswitches t...

Page 17: ...Level to be adjusted using the Data Up Down buttons Pattern Press the Pattern Store button to access the drum pattern function The currently selected drum pattern will be shown in the Display Use the...

Page 18: ...Marshall is a registered trademark of Marshall Amplification Plc Vox is a registered trademark of Korg UK Fender Matchless HiWatt and Mesa Boogie are trademarks of their respective companies and are i...

Page 19: ...to select the Red Cabinet type Adjusting Amp Parameters The Gain EQ and Level Parameters can be adjusted individually for the Green and Red Amp Channels The Gain ranges from 0 0 to 99 99 The Bass Mid...

Page 20: ...or Warped to create a completely new Amp HyperModel The procedure for Warping the Green and Red Amps together is as follows 1 With the GNX1 in Performance mode indicated by a yellow Status LED rotate...

Page 21: ...red in the number 1 location 6 Use the Data Up Down buttons to select the User location where the HyperModel will be saved If all locations have been used the Display will show the name of the HyperMo...

Page 22: ...ing knob for the selected Effect group Each Effect Parameter is labeled in the Matrix When a knob is turned the corresponding Parameter name will appear in the green alpha numeric Display and the Para...

Page 23: ...haracter to the right and the FX Edit button to select the previous character to the left 4 Repeat steps 2 and 3 until the desired Preset name shows in the Display 5 Once you have entered the desired...

Page 24: ...e of Wah Values include CRY Cry Wah is a traditional sounding Wah BOTIQU Boutique Wah is a wide sweeping Wah with a more modern sound and FULRNG Full Range Wah sweeps the entire spectrum of audible fr...

Page 25: ...r 2 Whammy The Number 3 Knob provides a manual control of the Whammy pedal position Ranges from 0 to 99 The Number 4 knob has no function when the Whammy is selected Intelligent Pitch Shifting IPS mak...

Page 26: ...Mid Level The Number 3 Knob adjusts the amount of mid range enhancement Ranges from G R MID 12 to 12 dB Treble Frequency The Number 4 Knob selects the frequency to which the boost will be applied by...

Page 27: ...the waveform used by the Flanger Waveforms include Triangle Sine and Square Parameter 5 Adjusts the left to right balance of the wet signal Ranges from L 99 to R 99 Mod Mix The Number 5 Knob controls...

Page 28: ...ob adjusts the rate SPEED at which the signal pans from side to side Ranges from 1 to 99 Parameter 2 The Number 3 Knob adjusts the intensity DEPTH of the changing pan Ranges from 0 to 99 Parameter 3 T...

Page 29: ...namics of your playing style Parameter 1 The Number 2 Knob adjusts the ATTACK of the synthesized voice Ranges from 0 to 99 Parameter 2 The Number 3 Knob adjusts the RELEAS of the synthesized voice Ran...

Page 30: ...r 4 Knob adjusts the level THRESH the input signal must reach before the Delay signal is attenuated Ranges from 0 to 99 and oF off Delay Level The Number 5 Knob adjusts the volume DLYLVL of the Delay...

Page 31: ...40 Create a HyperModel For this example we are going to use a vintage Tweed amp with an American 2x12 Cabinet and warp it with a Recitified Amp using a British 4x12 cabinet After selecting Preset 40...

Page 32: ...uit your personal taste To access these Red Channel Parameters press the Status button again All horizontal LEDs will light red indicating that all 5 knobs will now adjust the Red Channel Parameters R...

Page 33: ...betic charac ters until the Display reads RECTWD Then press the Amp Save button again This will take us to the second step of saving a HyperModel which is choosing one of the 9 User HyperModel locatio...

Page 34: ...ED lit rotate the Number 4 Knob until the Display shows SC HB This means that a single coil will sound like a Humbucker Turn the Compressor Off Next we didn t want to use compression in our Preset so...

Page 35: ...reen Channel s EQ adjustments The Display will briefly read EQ GRN EQ Green and the same knobs will adjust the same EQ Parameters for the Green Channel Adjust the Noise Gate For our example we wanted...

Page 36: ...d Press the Effect Select Down button again and the LED in the Delay row will light If the Display indicates that the Delay is on DLY ON press the Status button until the Display reads DLYOFF Delay Of...

Page 37: ...tton once and the second character begins to flash Use the Data Up Down buttons again until the flashing character is an X Press the Rhythm button again to Select the third character and change it to...

Page 38: ...See page 17 for more information on the storing procedure LFOs The GNX1 includes two assignable low frequency oscillators LFO1 and LFO2 which can be assigned to any of the same parameters available fo...

Page 39: ...k Controls the Compressor s Attack time CMPRTO Compressor Ratio Controls the Compressor s Ratio CMPTHR Compressor Threshold Controls the Compressor s Threshold CMPGAN Compressor Gain Controls the Comp...

Page 40: ...The GNX1 needs to be told whether you wish to use it in a stereo or mono mode In Stereo mode the GNX1 will produce a wide stereo image when the Right and Left Outputs are connected to two different am...

Page 41: ...th 99 requiring more pressure to engage The sensitivity may be auditioned while making adjustments The Display will read either WAH ON or WAHOFF depending on the status of the Wah as the V Switch enga...

Page 42: ...the alpha numeric Display shows MIDICH The numeric Display will show the currently selected MIDI channel 3 Press the Data Up Down to select the desired MIDI channel your choices include 1 through 16 a...

Page 43: ...se the Data Up Down buttons to select the destination User Amp number 7 Set the MIDI recording device to record 8 Press the Store button again The Display reads AMPSND until the dump is complete at wh...

Page 44: ...linking 4 This is your last chance to change your mind Pressing the Data Down or Exit button while the no is blinking in the Display will abort the Reset procedure 5 If you are sure that you want to r...

Page 45: ...CNTRY 16 PICKEN 17 PSTEEL 18 A MIXO Bank 7 ROCK 19 MO WAH 20 FAZOUT 21 THICKR Bank 8 CLEAN 22 ACOUST 23 CMPCLN 24 WRMCLN Bank 9 METAL 25 RECTFY 26 SOLO 27 WHAMMY Bank 10 STUDIO 28 STACKD 29 VOLSWL 30...

Page 46: ...Level CC 43 Red Mid Freq Coarse CC 44 Red Mid Freq Fine CC 45 Red Mid Level CC 46 Red Treble Freq Coarse CC 47 Red Treble Freq Fine CC 48 Red Treble Level CC 49 Parameter CC Amp Morph CC 79 Cabinet Mo...

Page 47: ...y Response 20 Hz 20 kHz 0 3 dB S N ratio Greater than 95 dB ref max signal 22kHz measurement bandwidth Total Harmonic Distortion Less than 0 04 1kHz Memory Capacity 48 Factory Presets 48 User Presets...

Page 48: ...RKWAY SANDY UTAH 84070 USA PH 801 566 8800 FAX 801 566 7005 DIGITECH GENETX AUDIO DNA AND GNX1 ARE TRADE MARKS OF THE HARMAN MUSIC GROUP INC COPYRIGHT THE HARMAN MUSIC GROUP PRINTED IN THE USA 02 2001...