Digital Monitoring Products
XR150FC/XR550FC Series Installation Guide
18
Expansion Modules
710 Bus Splitter/Repeater
Expands the number of devices and length of wire on the LX‑Bus or keypad bus.
Also provides wire connections for up to three additional LX‑Bus circuits.
ORDER: 710
711 Single Zone Expander
Single‑zone expander with screw terminal connections. Includes EOL resistors.
ORDER: 711
711S Single Zone Expander
Single‑zone expander with flying lead connections. Includes EOL resistor.
ORDER: 711S
714 Zone Expansion Module
Expander with four 5 VDC Class B zones and rotary‑switch addressing. Includes
EOL resistors and 12‑wire harness.
ORDER: 714
714‑8 Zone Expander
Terminal block installation for eight burglary or Class B non‑powered fire devices.
Includes enclosure with lock and key plus EOL resistors.
ORDER: 714‑8 , 714‑8‑R, 714‑8L‑G, 714‑8L‑R, 714‑8PCB
714‑16 Zone Expander
Terminal block installation for 16 burglary or Class B non‑powered fire devices.
Includes enclosure with lock and key plus EOL resistors.
ORDER: 714‑16 , 714‑16‑R, 714‑16L‑G, 714‑16L‑R, 714‑16PCB
715 Zone Expansion Module
Provides 4 Class B zones (12 VDC) for two‑wire smoke detectors and other
powered or non‑powered devices. Includes 3.3k EOL resistors and 12‑wire harness.
ORDER: 715
715‑8 Zone Expander
Provides eight powered zones (12 VDC) supporting two‑wire smoke detectors or
other fire alarm initiating devices. Includes red 340 enclosure and EOL resistors.
ORDER: 715‑8, 715‑8PCB, 715‑16PCB
715‑16 Zone Expander
Provides 16 powered zones (12 VDC) supporting two‑wire smoke detectors or
other fire alarm initiating devices. Includes red 340 enclosure and EOL resistors.
ORDER: 715‑16
716 Output Expander
Provides 4 programmable Form C (SPDT) relays and four open collector
annunciator outputs. Use the outputs for remote zone and system annunciation or
environmental control applications. Harness included.
ORDER: 716
717 Graphic Annunciator
Provides 20 annunciator outputs (open collector) that follow the armed or
bypassed state of the panel’s zones.
ORDER: 717
Auxiliary Modules
860 Relay Output Module
Provides electrical isolation between the alarm panel and other systems or for
switching voltage to control various functions.
ORDER: 860
865 Style W/X Notification
Circuit Module
Provides supervision for ground faults, opens and shorts on notification appliance
circuits. Suitable for use with style W or X 12 or 24 VDC circuits.
ORDER: 865
866 Style W Notification Circuit
Module
Supervises one Style W Notification circuit that supervises opens, shorts and
ground faults. Capable of switching 12 VDC internal or 24 VDC external power
supply.
ORDER: 866
867 LX‑Bus Notification Circuit
Module
Provides one supervised Style W circuit for 12 or 24 VDC notification devices.
The 867 connects to the LX‑Bus and supervises Ground Fault, Open and Short
conditions on the notification circuit.
ORDER: 867
869 Style D Class A Initiating
Circuit Module
Provides two Style D initiating 4‑wire circuits for waterflow switches and
nonpowered burglary and fire devices. Supervises both zones for Opens, Shorts
and Ground Fault conditions.
ORDER: 869
893A Dual Phone Line Module
Supervises the main and backup phone lines for sustained drop in voltage.
ORDER: 893A