24
Z-5010T Installation and Programming Guide | Digital Monitoring Products, Inc.
Display
The thermostat displays current room temperature and system settings like system mode,
fan mode, display lock, and Z-Wave network status. Degrees Celsius (C) are shown in
0.5 ° increments. Degrees Fahrenheit (F) are shown in 1 ° increments. The thermostat also
displays Heat and Cool icons to indicate when the system is heating or cooling.
Heat Icon
•
Solid: System is on and heating.
•
Blinking: System is on and heating. Minimum Run Time (MRT) delay is active.
Cool Icon
•
Solid: System is on and cooling.
•
Blinking: System is on and cooling. Minimum Run Time (MRT) delay is active.
Off
Heat-E
Cool
Auto
Select
Auto
On
Done
72F 80c
74
.5
F C
Low Batt
Fan mode
indicators
System mode
indicators
Text display line
Low battery indicator
Display lock indicator
Z-Wave network
installed indicator
Figure 14: Thermostat Display
Summary of Contents for SecureCom Smart Z-5010T
Page 1: ...INSTALLATION AND PROGRAMMING GUIDE Z 5010T Z Wave Thermostat MODE FAN Off Auto F...
Page 2: ......
Page 37: ......
Page 38: ......
Page 39: ......
Page 40: ...LT 1423 20175 2020 Digital Monitoring Products Inc...