12.4.5. Reset Inputs of the Module
The Reset Input is optionally used to connect a reset switch. The reset switch overrides the internal Reset
Controller.
Reset Inputs of the SM800/900
Signals
Value/Function
Used for
If used
If not used
ResetIn# (A79)
Manual Reset
Input
Switch to ground with
a momentary switch
Open
PWRBTN# (B31) ATX power switch
Input
Start the
computer
Switch to ground with
a momentary switch.
Open
AutoStart-Mode: (Default)
If X200A-Pin43 is open, then the Autostart-Mode is enabled and the PWRBTN is not needed to start.
ATX-Mode:
If X200A-Pin43 is pulled high with 470 Ohms to 5V, the system waits after VCC5SB is available until
the PWRBTN# is activated by pulling to GND.
12.4.6. LPC Bus of the Module
The LPC Bus is used to connect a secondary SuperIO chip, for an optional firmware hub and for the POD80
port. We recommend connecting all LPC signals to, at minimum, a 10pin header. Please see the sample
schematics. DIGITAL-LOGIC provides an LPC-POD analyzer to display the POD codes from the BIOS. The
LPC-Bus is length sensitive (maximum 20cm).
LPC Bus of the SM800/900
Signals
Value/Function
Used for
If used
If not used
LPC (A46-A58)
LPC-Bus
LPC-devices
Connect to LPC chips
and minimum to a
10pin header for the
POD80 analyzer
Open, not recommended
12.4.7. Suspend Outputs of the Module
The suspend signals are power control signals for controlling the external power generators. See the sample
schematics to better understand this function.
Suspend Outputs of the SM800/900
Signals
Value/Function
Used for
If used
If not used
SUSA# (A98)
No function
Internally pulled to 3.3V
Open
SUSB# (A99)
No function
Internally pulled to 3.3V
Open
SUSC# (A100)
Power control
Switch on/off
the external
3.3V, 5V or 12V
supplies
0 = Computer OFF
1 = Computer ON
connected to the gate of
a FET
Open
Normaly used, see
sample schematics
The SUSC# is an open collector signal that is pulled to GND when level is ‘0’ (on the SM800PCX). When
level is ‘1’ or ON, this signal is Z-State (on the SM800PCX), the motherboard will define the level as 3.3V or
5V with a 1k pullup resistor (TTL) or 100k in the case of a FET-Gate.
ATTENTION!
Never apply voltages over 5V or the
PM-controller will be destroyed!
Summary of Contents for SM800/900DK
Page 14: ...DIGITAL LOGIC AG SM800 900DK Technical Manual V1 2B 14 2 3 Block Diagrams 2 3 1 MSEBX800 900 ...
Page 23: ...DIGITAL LOGIC AG SM800 900DK Technical Manual V1 2B 23 4 1 Connector Plan ...
Page 36: ...DIGITAL LOGIC AG SM800 900DK Technical Manual V1 2B 36 5 3 Jumpers on the MSEBX800 ...
Page 48: ...DIGITAL LOGIC AG SM800 900DK Technical Manual V1 2B 48 12 1 2 PCB to SM800 900PC X Height ...
Page 89: ...DIGITAL LOGIC AG SM800 900DK Technical Manual V1 2B 89 ...
Page 90: ...DIGITAL LOGIC AG SM800 900DK Technical Manual V1 2B 90 ...
Page 91: ...DIGITAL LOGIC AG SM800 900DK Technical Manual V1 2B 91 ...
Page 92: ...DIGITAL LOGIC AG SM800 900DK Technical Manual V1 2B 92 ...
Page 93: ...DIGITAL LOGIC AG SM800 900DK Technical Manual V1 2B 93 ...
Page 94: ...DIGITAL LOGIC AG SM800 900DK Technical Manual V1 2B 94 ...
Page 95: ...DIGITAL LOGIC AG SM800 900DK Technical Manual V1 2B 95 ...
Page 96: ...DIGITAL LOGIC AG SM800 900DK Technical Manual V1 2B 96 ...
Page 97: ...DIGITAL LOGIC AG SM800 900DK Technical Manual V1 2B 97 ...
Page 98: ...DIGITAL LOGIC AG SM800 900DK Technical Manual V1 2B 98 ...
Page 99: ...DIGITAL LOGIC AG SM800 900DK Technical Manual V1 2B 99 ...
Page 100: ...DIGITAL LOGIC AG SM800 900DK Technical Manual V1 2B 100 ...
Page 101: ...DIGITAL LOGIC AG SM800 900DK Technical Manual V1 2B 101 ...