background image

Z-Wave

  Motion Sensor

User Guide   

DHS-ZW-SNMT-01

Works with:

VERA 2 / 3 / Lite

LAGOTEK 

Summary of Contents for DHS-ZW-SNMT-01

Page 1: ...Z Wave Motion Sensor User Guide DHS ZW SNMT 01 Works with VERA 2 3 Lite LAGOTEK...

Page 2: ...Using Motion sensor in Vera Scenes 9 Creating motion detected events in Vera scenes 9 Using Temperature Sensor in Vera Scenes 9 Creating conditions in Vera scenes based on temperature readings 10 Usin...

Page 3: ...sor can only communicate to devices within the same Z wave home network Always follow your controller s specific instructions for Z wave inclusion exclusion association or temperature reading Inclusio...

Page 4: ...cator light blinks 3 times rapidly 7 Mounting successful indicator light is on for 1 second Integration with Vera Home Controller MiCasaVerde Vera2 3 Lite refered later as Vera some minor differences...

Page 5: ...ed NWI mode is applicable for other Z Wave controllers and for simplicity this method is not presented here 4 Please press the tamper switch at the back of the device for 3 8 seconds 5 After 3 5 secon...

Page 6: ...ive 1 Open settings box for _Motion Sensor in Vera dashboard Go to Device Options tab 2 Click on Add configuration settings Fill out the fields a Variable type 2 b Data Size choose 2 byte hex c Desire...

Page 7: ...Size choose 2 byte hex c Desired Value type required Temperature Offset value e g 5 3 Click SAVE in Vera and wait till new settings are saved in Vera 4 Press the temper button on the device and keep i...

Page 8: ...and wait till new settings are saved in Vera 4 Press the temper button on the device and keep it for 3 7 seconds then release This is to wake up and propagate the settings device_type urn schemas mica...

Page 9: ...s tab Add Event Vera or New Scene Triggers Vera 3 Lite UI5 Device Motion sensor Type of Event A sensor door windiow motion etc is tripped Name whatever Tripped Yes 4 Create second scene in Vera in sta...

Page 10: ...e tool It is strongly recommended to read instructions on luup and luup codes in Vera scenes on http wiki micasaverde com for more details Creating conditions in Vera scenes based on illumination read...

Page 11: ...e sensor and try to include it again Q Why doesn t the Z Wave sensor detect any movement A 1 The Z Wave sensor isn t included in a Z Wave network Include it and try it again 2 The batteries are almost...

Page 12: ...sleep mode the device is not active listening the device will wake up according to the wakeup command class Include Initiator The include initiator is used when Primary and Inclusion Controllers inclu...

Page 13: ...off time is done a basic off message is sent to the associated node Default value 0x0A8C 2700 sec 45 min Size 2 bytes integer Param1 the most significant byte of the integer Param2 the least significa...

Page 14: ...device will send an unsolicited report to the controller if the status is changed the value 0x00 will indicate that the tamper is placed correctly on the wall The value 0xFF will indicate a tamper ala...

Reviews: