EVO Control Panel
31
13.10 Partitioning
S
ECTION
[3031]: O
PTIONS
[1]
TO
[8]
(default =
partition 1 enabled
) The control panel can provide up to eight
completely independent partitions. Most features and options can be
independently set for each partition. All zones, keyswitch zones, user codes
and system modules are assigned to specific partitions. The EVO48 only
has 4 partitions.
13.10.1 Panel Partition Assignment
S
ECTION
[3020]
(default =
00
) The control panel will report system events as originating
from one or all enabled partitions. The System Troubles can only be viewed
through the partitions enabled in this section. Enter a 2-digit decimal
number from 01 to 08 which represent partitions 1 to 8. Enter 00 to disable
this feature.
13.11 Shabbat Feature
S
ECTION
[3030]: O
PTION
[4]
(default =
disabled
) When enabled, addressable detectors and keypads in
the system no longer display system status through the LCD and/or LEDs
between noon Friday and midnight Saturday. Normal operation is re-
instated Sunday at 12:00:01a.m. A user can access all the usual
commands and features during the Shabbat period by pressing a key or by
entering their access code (depending on how Confidential Mode is
configured in the keypad). When no actions have occurred for two minutes,
the Shabbat feature will re-activate. During the Shabbat period:
• the LCD keypads only display the date and time
• the backlight is disabled
• the LED indicators on modules are disabled
13.12 Installer Function Keys
Press and hold the
[0]
key and key in the
[
INSTALLER
CODE
]
to access the
installer functions and then:
For LCD keypads:
Press the key indicated in the list below that
corresponds to the function you wish to activate.
For Grafica keypads:
Press the center action key (
Options
), highlight the
desired function and then press the center action key (
Ok
).
13.13 Module Reset
S
ECTION
[4001]
To reset a module connected to the combus to its default values, key in the
module's serial number into section
[4001]
.
13.14 Locate Module
S
ECTION
[4002]
To locate a specific module on the combus, key in the module's serial
number into section
[4002]
. The LED on the module flashes until the serial
number is entered or the module’s tamper or unlocate switch is pressed.
13.15 Module Programming
S
ECTION
[4003]
To program a module, enter section
[4003]
to enter
Module Programming
Mode
on page 8), and enter the module's serial number. To
exit, press the
[
CLEAR
]
key until Normal Mode is displayed.
13.16 Module and Label Broadcast
S
ECTION
[4004]
Module Broadcast
To copy the contents of the programming sections from one module to
another, enter the serial number of the source module in section
[4004]
,
enter the serial numbers of all the destination modules and press
[
ACC
]
or
the center action key (
Start
).
Label Broadcast
Copy the User Labels, Zone Labels (sections
[0301]
to
[0396]
), the Door
Labels (sections
[2301]
to
[2332]
) and the Partition Labels (sections
[3100]
,
[3200]
,
[3300]
,
[3400]
,
[3500]
,
[3600]
,
[3700]
and
[3800]
) to all the
modules in the system that support these labels. To transmit the labels, in
section
[4004]
, enter the control panel’s serial number. From the
Destination screen, do not enter a serial number and press
[
ACC
]
if using an
LCD keypad or the center action key (
Start
) if using a Grafica keypad.
The Module and Label Broadcast feature will only work when a module is
broadcasting its data to a module or to modules of the same type and model number.
13.17 System Date & Time
The System Date and Time is programmed through the User Menu.
13.18 Quick Module Scanning
S
ECTION
[4005]
After entering the section, the control panel will scan all addresses
assigned to modules. If any missing modules are detected (i.e. detector
removed from the combus), the control panel will erase the module's serial
number, removing the module from the control panel's memory.
13.19 Module Scanning
S
ECTION
[4006]
After entering the section, the control panel will scan all addresses on the
combus. If any missing modules are detected (i.e. detector
removed from the combus), the control panel will erase the module's serial
number, removing the module from the control panel's memory.
If new modules are detected, the serial number will be entered in the
control panel’s memory.
13.20 Serial Number Viewing
S
ECTION
[4000]
Enter section
[4000]
to view the serial number of the control panel and all
the modules on the combus. The firmware version of some modules will be
displayed as well (e.g. (XXXXXXXX) VXX.XX).
For LCD Keypads:
The keypad will display the control panel’s serial
number. Use the
[
]
and
[
]
keys to scroll.
For Grafica Keypads:
The keypad will display the control panel’s serial
number. Press the center action key (
Next
) to scroll.
13.21 Power Save Mode
S
ECTION
[3033]: O
PTIONS
[4]
(default =
enabled
) When enabled and the control panel is running on the
backup battery, the control panel can set all keypads into Power Save
Mode. The keypad's backlight and LEDs are disabled until a key is pressed,
an alarm occurs or an Entry Delay is triggered.
[1]
Partition 1
[3]
Partition 3
[5]
Partition 5
[7]
Partition 7
[2]
Partition 2
[4]
Partition 4
[6]
Partition 6
[8]
Partition 8
[
STAY
]
TEST REPORT: Sends the
Test Report
report code programmed
in section
[3902]
to the monitoring station.
[
FORCE
]
CALL WINLOAD: Dials the PC telephone number programmed
in section
[3010]
to communicate using WinLoad.
[
ARM
]
ANSWER WINLOAD: Forces the control panel to answer a call
made by the monitoring station that is using WinLoad.
[
DISARM
]
CANCEL COMMUNICATION: Cancels all communication with
the monitoring station or WinLoad until the next reportable event.
[
MEM
]
INSTALLER TEST MODE: Perform walk tests where the bell or
siren squawks once when a zone opens and twice when it
closes. Press
[
MEM
]
again to exit. Partitions cannot be armed if
the Installer Test Mode is enabled.
[
TRBL
]
START MODULE SCAN: Verifies the status of modules on the
combus. The LCD Keypads display the serial number of each
module connected to the combus.
[
ACC
]
START VOLTMETER READING (EVO641 only): Verifies if the
combus is supplying enough power at the keypad’s location.