background image

One-zone Hardwire Module V2.0

(DGP2-ZX1)

Instructions

DGP2ZX1-EI02

The 

One-zone Hardwire Module

 

(DGP2-ZX1)

 is an interface

between the Digiplex (DGP-48) or DigiplexNE (DGP-NE96) control
panels and any hardwired detection devices. The DGP2-ZX1
connects to the Digiplex/DigiplexNE control panels’ communication
network providing you with one additional hardwired input. 

I

NSTALLATION

The DGP2-ZX1 modules are connected to the control panel’s
communication network in a star and/or daisy chain configuration.
The communication network consists of four wires that provide
power and two-way communication between the control panel and
all modules connected to it. Connect the four terminals labeled red,
black, green, and yellow of each DGP2-ZX1 to the corresponding
terminals on the control panel as shown in Figure 1 on the back of
this instruction. Please refer to the appropriate control panel’s

Installation & Reference Manual

 for maximum allowable installation

distance from the control panel. 

Z

ONE

 C

ONNECTIONS

Each DGP2-ZX1 has one hardwired input terminal that will allow
you to connect up to two (with ATZ enabled) non-bus detection
devices to the Digiplex/DigiplexNE system. Each device connected
to the DGP2-ZX1’s input terminal must be assigned to a zone in
the control panel and the zone’s parameters must be defined. For
more information, please refer to the appropriate control panel

Installation & Reference Manual

. The DGP2-ZX1 will communicate

the status of the zones to the control panel through the
communication network. Connect the devices to the DGP2-ZX1 as
shown in Figure 1 on the back of this sheet. 

The DGP2-ZX1 follows the ATZ and EOL definitions set
in the Digiplex/DigiplexNE control panels.

P

ROGRAMMING

 M

ETHOD

From any keypad connected to the communication network: 

Please note that the serial number is located on the DGP2-ZX1’s
PC board. We recommend that you use the DGP2-ZX1’s
programming sheet found in the 

Digiplex/DigiplexNE Modules’

Programming Guide

 to keep track of what was programmed and

how. This module can also be programmed using the control
panel’s 

Module Broadcast Feature

 (refer to the appropriate control

panel

 Installation & Reference Manual

) as well as through the

WinLoad Security Management  Software (refer to the 

WinLoad

Software Help File

 for more information).

The DGP2-ZX1 comes equipped with an on-board tamper switch.
When option 

[1]

 is enabled in section 

[001]

 and the tamper switch

is triggered, a Module Tamper report will be sent to the control
panel via the communication network. 

I

NPUT

 S

PEED

 T

IMINGS

The input speed defines how quickly the input terminal on the
DGP2-ZX1 responds to an open zone. The control panel will only
respond if the zone remains open for the duration of the Input
Speed. All other zone definitions and options don’t come into effect
until the control panel has responded. This feature prevents any
momentary glitches from causing an alarm or unnecessary
reporting.

Input Speed = Base Time x Time Value. 

This section determines the unit of time to be multiplied by the
Time Value. 
000 = 15 milliseconds
001 = 1 second
002 = 1 minute

Enter a 3-digit decimal value between 001 and 255. This decimal
value will be multiplied by the Base Time to determine the input
speed. 

For example, if section 

[002]

 = 001 and section 

[003]

 = 030,

the Input Speed will be 30 seconds.

 

S

PECIFICATIONS

On-board tamper switch:

Yes

Voltage:

9-16 VDC

Current consumption:

28mA maximum

Number of inputs:

1

Number of zones:

1 (2 with ATZ enabled) standard zone 

Input speed:

15ms - 255 minutes

Power-up indication:

Green LED illuminated

Proper operation:

Red LED flashes

Locate indication:

Green LED flashes

Communication Fault
Indication:

Green and red LEDs flash alternately 

Locate deactivation:

Press tamper switch

Humidity:

95% maximum

STEP 1: Press and hold the 

[0]

 key

STEP 2: Enter the 

[

INSTALLER

 

CODE

]

 

STEP 3: Enter section 

[953]

 (DGP-48) / 

[4003]

 (DGP-NE96)

STEP 4: Enter the DGP2-ZX1’s 8-digit 

[

SERIAL

 

NUMBER

]

STEP 5: Enter the 3-digit 

[

SECTION

]

 you want to program

STEP 6: Enter the required data

Section [001] - Option [1]

Tamper Recognition

Section [002]

Base Time

Section [003]

Time Value

All manuals and user guides at all-guides.com

all-guides.com

Reviews: