RF112IRG Rev1.6 P/N DF2382
RF112 - SMART RF
Wireless Contact /Shock
Sensor / Analyser
E
LE
C TRONI
C
S
D
IGIFLE
X
SE
CURITY
®
Installation Reference Guide
C
17.4mm
13.5 mm
54 mm
134 mm
29.6 mm
30.4 mm
?
For Further Information See Your
Control Panel Installation Manual
Panasonic CR123A Lithium
Duracell DL123A
3.0 VDC
0-93% Relative Humidity
Non-condensing
Functional range: -10°C to +49°C
EN5013-5 Class II Only: -10°C to +40°C
433.42 Mhz
1
Push the screwdriver blade
3mm into the slot shown.
Do Not twist the blade!
B
Lift the screwdriver away from the
base to release the cover. Do not
twist or rotate the screwdriver.
D
IGIFLE
X
P
TY
L
TD
18 Brumby Street
Seven Hills NSW 2147, AUSTRALIA
Phone:
(+612) 97417000
Email: [email protected]
Web: www.digiflex.com.au
Our Vision Is Your Peace Of Mind
The RF112 Ships With The Following Items
RF112 Printed Wiring Assembly
RF112 Housing Including Cover And Mounting Plate
Double Sided Adhesive Tape To Suit Above Housing
Magnet Housing Including Cover And Mounting Plate
Double Sided Adhesive Tape To Suit Above Housing
Neodymium Magnet
CR123A Lithium Battery
5 x Mounting Screws and 1 x Case Lock Screw
RF112IRG Installer Reference Guide
Mounting
Screw
Mounting
Screw
Tamper
Screw
!
Panasonic : CR123A
Duracell : DL123A
Do Not Lift
By Antenna
2
4
5
Cable Entry
Knockout
Tamper
Case Front
Tamper
End Of Line Resistor (EOL)
For further information refer
to Control Panel EOL Selection
3V D.C. Output
Powering external devices from this
output will reduce battery life.
Shock Sensor/Rope Contact Input
For further information refer to
Control Panel Install Manual
ZONE
Alarm
N/C
(EOL)
ZONE
Tamper N/C
(EOL)
Alarm
N/C
TAMPER
6
Single EOL
EOL Alarm+Tamper
(EOL)
1
2
1
2
3
4
5
6
3
RF ID is located on the
side of the battery holder.
Move
Plastic Tab
Lift PWA Out
Rev1.6
Case Locking Screw
10mm
Max
4G x10
Philips #1
A
The RF112 is supplied with a double sided tape
mounting option. Use this mounting method to speed
installation where appropriate.
Follow the guidelines below for best results.
1) Do not use on rough or uneven surfaces.
2) Clean both surfaces using isopropyl alcohol wipes
before installing tape.
3) Test zone function to ensure correct placement before
removing backing tape.
4) Apply firm pressure to the device for 30 seconds
after placement to ensure the adhesive activates. (The
adhesive is pressure activated)
7
6 Slow Flashes
Device Powered Up
4 Fast Flashes
Device Has been Configured
Continuous Flash
Device TX or RX
Single Pulse
Device Input Triggered
When panel is in service mode and device Tamper is
triggered, the LED will activate for up to 15 minutes
to assist with device placement and configuration.
During normal operation the LED is off to extend
battery life.
8
LED Indicator
Contact Wiring Distance = 8m MAX
All other external peripherals = 1m MAX
3= 3V OUT
4= GND
5= INPUT 2
6= COMMON
TERMINALS
1= INPUT 1
2= COMMON
Ensure that the transmitter is protected from
weather elements such as extreme temperatures,
humidity, rain or snow.
Using Adhesive Mounting
Opening The Housing
Removing The PWA
Mounting
Wiring
Battery Installation
RF ID
Input 1
Input 1
Input 2