DigiDesign 888/24 I/O Installation Manual Download Page 14

 

888/24 I/O

 

10

 

8  

 

After you have made the desired changes, 

replace the top of the 888/24 I/O.

 

9  

 

Replace the four front panel screws using 

the hex wrench.

 

10  

 

Replace the top screws with a Phillips 

screwdriver.

 

Changing the Default Word 
Clock Lock Port of the 
888/24 I/O in D/A Stand-
Alone Mode

 

The 888/24 I/O defaults to “listening” to a 
digital word clock signal on channels 1-2 of 
its AES/EBU digital input ports. If you wish 
to use a S/PDIF device as your source of 
word clock, you must reset this default by 
opening the 888/24 I/O and moving an in-
ternal jumper switch so that channels 1-2 
of its S/PDIF digital input ports are used in-
stead. 

 

 

Refer to Figure 1 and 2 for details on jumper 

 

switches and their default positions.

 

To change the default word clock lock port of 
the 888/24 I/O in stand alone D/A mode:

 

1  

 

Make sure that your computer and 

888/24 I/O are turned off.

 

2  

 

With a Phillips screwdriver, remove the 

screws from the top of the 888/24 I/O. 

 

3  

 

Using the 1/16 inch hex wrench in-

cluded with the 888/24 I/O, carefully re-
move the front four panel screws as noted 
on the bag containing the hex wrench.

 

4  

 

Lift the top off of the 888/24 I/O.

 

5  

 

Inside the left-front of 888/24 I/O’s chas-

sis, near the large FPGA chip, is a set of 
three jumper switches, each with a remov-
able cap. Each of these switches controls a 
different default function which is shown 
in Figure 1 and 2. 

 

6  

 

Locate the jumper switch for the word 

clock lock default (the back-most jumper) 
and gently lift the cap off the 3-pronged 
connector. 

 

Figure 1.   jumper switch location in the 888/24 I/O

Figure 2.  Changing jumper switch settings

stand alone mode

default word clock lock switches

AES/EBU or S/PDIF

stand alone mode

default sample rate switches

44.1 kHz or 48 kHz

stand alone mode

DAC muting switches

in this position

DACs are muted

in this position
44.1 kHz is selected

44.1 kHz

48 kHz

unmute DA

Cs

mute DAC

s

AES/EBU

S/PDIF

remove jumper and

place it in desired position

Summary of Contents for 888/24 I/O

Page 1: ...fax 650 842 7999 Technical Support USA 650 842 6699 650 856 4275 Product Information 650 842 6602 800 333 2137 Fax on Demand 1 888 USE DIGI 873 3444 World Wide Web www digidesign com Digidesign FTP Si...

Page 2: ...was tested for CISPR compliance under conditions that included the use of peripheral devices and shielded cables and connectors between system components Digidesign recommends the use of shielded cabl...

Page 3: ...t Sample Rate of the 888 24 I O in A D Stand Alone Mode 9 Changing the Default Word Clock Lock Port of the 888 24 I O in D A Stand Alone Mode 10 Muting the DAC Outputs of the 888 24 I O in A D Stand A...

Page 4: ...888 24 I O iv...

Page 5: ...endent stand alone 24 bit audio converter in your studio If you own a Pro Tools system most of the information in this guide is covered in your Pro Tools TDM Hardware Installation Guide The 888 24 I O...

Page 6: ...rst Pro Tools card in your system This Audio Interface will act as the master inter face in your system All other Audio Inter faces will be slaved to it Because some digital audio devices do not outpu...

Page 7: ...are monitored on screen in the Pro Tools software The 888 24 I O is factory calibrated so that a meter reading of 18 dB corresponds to the 888 24 I O nominal operating level which can be set to either...

Page 8: ...osen for that channel The 888 24 I O analog audio connectors are balanced XLRs with pin 2 wired hot or pin 3 cold or and pin 1 ground 3 AES EBU Digital Outputs 1 8 The 888 24 I O AES EBU output jacks...

Page 9: ...inuously ac tive on both the AES EBU and S PDIF out put jacks regardless of which digital input format is selected for channels 1 2 To avoid RF interference use 75 ohm coaxial cable for S PDIF transfe...

Page 10: ...dBu levels it should be placed over the rear two prongs For 10 dBV levels it should be placed over the front two prongs 6 After you have made the desired changes replace the top of the 888 24 I O 7 R...

Page 11: ...ut levels It is important that you determine which line level mode is appropriate for your stu dio In 4 dBu operating mode the 888 24 I O is a 24 bit digital audio device capable of producing audio si...

Page 12: ...erter 1 Turn off any digital devices that may send a word clock signal to the 888 24 I O channel 1 2 digital input ports 2 Turn on the 888 24 I O The 888 24 I O searches briefly for a word clock signa...

Page 13: ...ools Changing the Default Sample Rate of the 888 24 I O in A D Stand Alone Mode The default sample rate of the 888 24 I O in stand alone A D mode is 44 1kHz If you wish to change this default setting...

Page 14: ...2 With a Phillips screwdriver remove the screws from the top of the 888 24 I O 3 Using the 1 16 inch hex wrench in cluded with the 888 24 I O carefully re move the front four panel screws as noted on...

Page 15: ...tput mute setting of the 888 24 I O in stand alone D A mode 1 Make sure that your computer and 888 24 I O are turned off 2 With a Phillips screwdriver remove the screws from the top of the 888 24 I O...

Page 16: ...888 24 I O 12...

Page 17: ...s Sample Rate 44 1 kHz or 48 kHz 10ppm Clock Reference Super Clock 256x sample clock In Out BNC connectors additional clock refer ences supported via Digidesign s Universal Slave Driver SMPTE Slave Dr...

Page 18: ...01dB 1kHz 20 Hz 20 kHz band limited Maximum Output Level 26 dB channel bridging loads Frequency Response 1dB 20 Hz 20 kHz Physical Specifications Power requirements 90 260 VAC 47 63 Hz 30 VA auto swi...

Page 19: ...an interface such as the 888 24 I O the meters are calibrated in decibels below peak digital clipping level Headroom The concept of headroom is slightly differ ent for analog and digital devices Analo...

Page 20: ...ro Tools 4 x for calibration in structions The Pro Tools Installer includes several pre configured calibration session templates that cover most common calibration set ups You can use these in additio...

Page 21: ...gn the inputs to match the reference level When the level is properly matched the track name will stop flashing The Automatch indicator arrows on each track show the direction of adjustment re quired...

Page 22: ...888 24 I O 18...

Page 23: ...an interface such as the 888 24 I O the meters are calibrated in decibels below peak digital clipping level Headroom The concept of headroom is slightly differ ent for analog and digital devices Analo...

Page 24: ...lica tion available on your Pro Tools Installer CD ROM to calibrate the outputs and in puts of the 888 24 I O If you are using Pro Tools 5 0 or later refer to Appendix B Calibrating the 888 24 I O Pro...

Page 25: ...brate the 888 24 I O with Calibration Tool using an external source 1 Start the Calibration Tool application 2 In the Headroom field enter the amount of headroom you desire The default setting for the...

Page 26: ...I O with Calibration Tool using an external VU meter 1 In the Calibration Tool software select 1 kHz from the Frequency pop up menu and click the oscillator setting to On 2 Adjust the 888 24 I O Outpu...

Reviews: