Using the 882/20 I/O
7
▲
In stand-alone mode, the 882/20 only op-
erates at a 44.1kHz sample rate. If you wish
to convert analog signals into 48kHz digital
audio, you must launch Pro Tools (or any other
software which supports the 882/20 I/O) to
change the default sample rate.
To use the 882/20 I/O as a stand alone D/A
converter:
1
Make sure that a digital device providing
a word clock signal is connected to the
S/PDIF input of the 882/20 I/O and that
the device is powered on.
2
Turn on the 882/20 I/O. The 882/20 I/O
will search for a valid word clock on its
S/PDIF input.
3
When a valid word clock lock is recog-
nized, the 882/20 I/O will enter digital
sync mode and function as a stand-alone
D/A converter using the S/PDIF input and
analog outputs 1–2.
The 882/20 I/O sample rate is determined
by the sample rate that it detects on its
S/PDIF input.
To return the 882/20 I/O to Pro Tools-based
operation:
◆
Turn on your computer.
– or –
◆
If your computer is on, launch Pro Tools.