AT commands
Diagnostic interface commands
Digi XBee Cellular LTE Cat 1 Embedded Modem User Guide
64
Parameter range
0 - 0xFFFF [read-only]
Default
Set in the factory
HS (Hardware Series)
Read the device's hardware series number.
Parameter range
N/A
Default
Set in the factory
CK (Configuration CRC)
Displays the cyclic redundancy check (CRC) of the current AT command configuration settings.
Parameter range
0 - 0xFFFFFFFF
Default
N/A
Diagnostic interface commands
The following AT commands are diagnostic interface commands.
DI (Device Cloud Indicator)
Displays the current Device Cloud status for the XBee.
Range
Value
Description
0x00
Connected
0x01
Before connection to the Internet
0x02
Device Cloud connection in progress
0x03
Disconnecting from Device Cloud
0x04
Not configured for Device Cloud
Default
N/A