API frames
Socket Listen Response - 0xC6
Digi XBee® 3 Cellular LTE-M/NB-IoT Global Smart Modem User Guide
284
Socket Listen Response - 0xC6
Description
The device sends this frame in response to a
frame.
Format
The following table provides the contents of the frame. For details on frame structure, see
Field name
Field
value
Data type
Description
Frame type
0xC6
Byte
Frame ID
Byte
Resource identifier used to match
status responses.
Socket ID
Byte
The socket ID of the socket that has
started listening.
Status
Byte
Status code. See table below.
The following table shows the status codes.
Code
Description
0x00
Success
0x01
Invalid port
0x02
Error
0x03
Already bound or listening
0x20
Invalid socket ID