Extended Socket frames
Extended Socket example: UDP
Digi XBee® 3 Cellular LTE-M/NB-IoT Global Smart Modem User Guide
170
Send to Digi echo server
Digi hosts a server at 52.43.121.77 port 10001 which echos all UDP traffic sent to it.
Field
Value
Frame type
(Socket SendTo)
Frame ID
0x01
Socket ID
0x00
Destination Address
0x34 0x2B 0x79 0x4D (52.43.121.77)
Destination Port
0x27 0x11 (decimal 10001)
Transmit Options
0x00
Payload
echo this
Socket SendTo frame data:
7E 00 13 45 01 00 34 2B 79 4D 27 11 00 65 63 68 6F 20 74 68 69 73 E5
Receive TX Status
Extended sockets use the existing TX Status frame (
) to report acceptance of the data for
transmit.
Field
Value
Frame type
(TX Status)
Frame ID
0x01
Status
0x00 (Success)
TX Status received from XBee:
7E 00 03 89 01 00 75
Receive echoed data
When the response from the server is sent back, the XBee provides it using a Socket Receive From
frame.
Field
Value
Frame type
(Socket Receive From)
Frame ID
0x00
Socket ID
0x00