Save the changes to the ini file.
Finally download and install the latest version of Flashwriter
http://ftp1.digi.com/support/firmware/FlashWriter.msi
4
PERFORM LOW LEVEL TESTS
Connect the serial port of the PC to the WR41V1 using the serial cable.
From the command line run the imxtest program including as an argument the PC com port number:
imxtest -p 1
(E.g. for COM port 1)
imxtest -p 2
(E.g. for COM port 2)
Hold the reset button in and then power up the WR41V1. This may take a little practise.
Check the output of the imxtest program. If the test passes then the following output will be seen:
If the SDRAM, FLASH or SRAM test fails then the product should be returned via RMA. When requesting
the RMA please include the appropriate fail reason: