Serial port
Configure Modbus mode
TX54 User Guide
211
i. Add a destination:
(config)> add serial port1 upd destination end
(config serial port1 udp destination 0)>
ii. (Optional) Enter a description of the destination:
(config serial port1 udp destination 0)> description
string
(config serial port1 udp destination 0)>
iii. Set the host name or IP address of the remote site to which data should be sent:
(config serial port1 udp destination 0)>hostname
hostanme-or-IP-
address
(config serial port1 udp destination 0)>
iv. Set the port number of the remote site to which data should be sent:
(config serial port1 udp destination 0)> port
port
(config serial port1 udp destination 0)>
19. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
20. Type
exit
to exit the Admin CLI.
Depending on your device configuration, you may be presented with an
Access selection
menu
. Type
quit
to disconnect from the device.
Configure Modbus mode
Modbus
mode allows you to use the serial port for Modbus. See
To change the configuration to match the serial configuration of the device to which you want to
connect:
WebUI
1. Log into the TX54 WebUI as a user with Admin access.
2. On the menu, click
System
. Under
Configuration
, click
Serial Configuration
.
The
Serial Configuration
page is displayed.
Summary of Contents for TX54
Page 1: ...TX54 User Guide Firmware version 22 2 ...
Page 190: ...Interfaces Bridging TX54 User Guide 190 ...
Page 293: ...Hotspot Hotspot configuration TX54 User Guide 293 ...
Page 332: ...Hotspot Show hotspot status and statistics TX54 User Guide 332 ...
Page 584: ...Services Simple Network Management Protocol SNMP TX54 User Guide 584 4 Click Download ...