AT commands
Command mode options
XBee Wi-Fi RF Module User Guide
177
CT (Command Mode Timeout)
Sets or reads the period of inactivity (that is, no valid commands received) after which the RF module
automatically exits AT Command Mode and returns to Idle Mode. This time period can be up to ten
minutes.
Parameter range
2 - 0x1770 (x 100 ms)
Default
0x64 (10 seconds)
CN (Exit Command mode)
Immediately exits Command Mode and applies pending changes.
Note
Whether Command mode is exited using the
CN
command or by
CT
timing out, changes are
applied upon exit.
Parameter range
N/A
Default
N/A
GT (Guard Times)
Set the required period of silence before and after the command sequence characters of the
Command mode sequence (
GT
+
CC
+
GT
). The period of silence prevents inadvertently entering
Command mode.
Parameter range
0x2 - 0x0576 [x 1 ms] (max of 1.4 seconds)
Default
0x3E8 (one second)
CC (Command Mode Character)
Sets or reads the command mode character used between guard times of the AT Command Mode
Sequence (
GT
+
CC
+
CC
+
CC
+
GT
). This sequence allows the module to enter into AT Command
Mode.
Parameter range
0 - 0xFF
Default
0x2B (the ASCII plus character:
+
)