AT commands
Output Control
XBee Wi-Fi RF Module User Guide
168
M0 (PWM0 Duty Cycle)
Sets the duty cycle of PWM0 for P0=2, where a value of 0x200 is a 50% duty cycle.
Parameter range
0 - 0x3FF
Default
0
M1 (PWM1 Duty Cycle)
Sets the duty cycle of PWM1 for P1=2, where a value of 0x200 is a 50% duty cycle.
Parameter range
0 - 0x3FF
Default
0
Output Control
The following AT commands are output control commands.
IO (Set Output Pins)
Set output pins to the designated level. Bit 0 corresponds with DIO0 and bit 1 with DIO1, up to bit 19
that corresponds with DIO19. See
for a functional description.
Parameter range
0 to 0x7fff on TH
0 to 0xfffff on SMT
Default
N/A
OM (Output Mask)
Sets the output mask for the IO command. If you set a bit, the corresponding bit in the IO command is
enabled. If it is clear, then that same bit has no effect in the IO command.
Parameter range
0 to 0x7fff on TH
0 to 0xfffff on SMT
Default
0 to 0x7fff on TH
0 to 0xfffff on SMT