Alerts and notifications
Configure alerts for Automatic Device Recognition (ADR)
Digi CM User Guide
62
7
Select an action and enter the keyword for the port event handling.
8
Enable Email notification.
Note
It is assumed that SMTP is configured first. If not, see Configuring SMTP alerts.
9
Enter the title of the Email (subject line).
10
Enable or Disable Case sensitive.
11
Enter the Email recipient’s address.
12
Enable SNMP trap notification.
13
Enter the title of the trap.
14
Choose either to use the global SNMP settings by enabling "Use global SNMP configuration" or
specify special settings for this port.
15
Enter the IP address of the trap receiver.
16
Enter the SNMP community
17
Select the version.
18
Complete configuration and then choose
Save & apply
.
Note
Key word is any text string that will trigger an alert when it traverses the serial port.
Configure alerts for Automatic Device Recognition (ADR)
Before configuring the alerts for Automatic Device Recognition, be sure you have configured the
port for ADR as described in
Configure Automatic Device Recognition
1
Access the web interface.
2
Under the
Serial Port
heading, Click
Configuration
.
3
Choose All or an Individual port >
Alert Configuration
.
4
Follow the Email Alert steps to configure the email alert or follow the SMTP Notification to
configure SMTP.
5
Complete configuration and choose
Save & apply
.
Email Alert
SMTP Notification
Enable "Email Alert for active detection"
Enter the Title of email
Enter Name and email address where the
email should be sent.
Enable "Active detection trap"
Configure the trap receiver by one of the following
two ways:
Enter "Use global SNMP configuration" OR
Enter the IP address of the trap receiver, the SNMP
trap community and select the version
Summary of Contents for Digi CM 16
Page 1: ...User Guide Digi CM 8 port 16 port 32 port and 48 port...
Page 63: ...Digi CM User Guide 63 User administration Administer users 64...
Page 130: ...Power Controller Cascade multiple Digi RPM units Digi CM User Guide 130...
Page 131: ...Digi CM User Guide 131 Port clustering Introduction 132 Configure port clustering 132...