Configuration and management
Exit the command line interface
Digi Connect IT® 16/48 User Guide
38
The device is also accessible at the default IP address of
192.168.210.1
. However,
because this IP address does not use a DHCP server, to connect to this address you
must configure your local PC with an appropriate static IP address (for example,
192.168.210.2).
2. At the login prompt, enter the username and password of a user with Admin access:
login: admin
Password: **********
The default username is
admin
. The default unique password for your device is printed on the
device label.
3. Depending on the device configuration, you may be presented with another menu, for example:
Access selection menu:
a: Admin CLI
1: Serial: port1
(9600,8,1,none,none)
q: Quit
Select access or quit [admin] :
Type
a
or
admin
to access the Connect IT 16/48 command line.
You will now be connected to the Admin CLI:
Connecting now, 'exit' to disconnect from Admin CLI ...
>
See
for detailed instructions on using the command line interface.
Exit the command line interface
Command line
1. At the command prompt, type
exit
.
> exit
2. Depending on the device configuration, you may be presented with another menu, for example:
Access selection menu:
a: Admin CLI
1: Serial: port1
(9600,8,1,none,none)
q: Quit
Select access or quit [admin] :
Type
q
or
quit
to exit.