Display Commands
9.1.16
9.1.16 Read Character Encode/Decode Mode
Code
Hexadecimal
ESC [ u
1B 5B 75
Description:
This command returns the current compatibility mode. The response format is as shown below.
Response:
Code
Hexadecimal
ESC [ <
n
> u
1B 5B <
n
> 75
n
is a ASCII coded decimal number.
n
Display Mode
0
ASCII Encode/Decode mode
1
UTF-8 Encode/Decode mode
2
UTF-16 Encode/Decode mode
Notes:
1.
This command is not supported in USB mode.
9.1.17
9.1.17 Start Self-Test
Code
Hexadecimal
ESC [ 0 ?
1B 5B 30 3F
Description:
This command starts a self-test in an endless loop. The self-test stops and returns to normal operation
when the device received any data.
9.1.18
9.1.18 Restore Configuration Data to Factory Default
Code
Hexadecimal
ESC + 0 w
1B 2B 30 77
Description:
This command restores all settings to the factory default configuration.
Copyright © 2022, Diebold Nixdorf
01750364416 B