Display Commands
9.1.14
9.1.14 Set Serial Port
Code
Hexadecimal
ESC [ <
b
>;<
d
>;<
p
>;<
s
> s
1B 5B <
b
> 3B <
d
> 3B <
p
> 3B <
s
> 73
Description:
This is an alternate command to set the serial communication settings. The parameters are ASCII coded
decimal values or alphabetical character:
Parameter
Values
b
Baud rate
9600 to 115200
d
Data length
7 or 8
p
Parity
0 = none
1 = odd
2 = even
s
Stop bit
1 or 2
Notes:
1.
This command is not applicable in USB mode.
9.1.15
9.1.15 Set Character Encode/Decode Mode
Code
Hexadecimal
ESC [ <
n
> u
1B 5B <
n
> 75
n
is a ASCII coded decimal number defined as follow:
n
Display Mode
0
Set ASCII Encode/Decode mode
1
Set UTF-8 Encode/Decode mode
2
Set UTF-16 Encode/Decode mode
Description:
An encode/decode mode change resets the display.
Copyright © 2022, Diebold Nixdorf
01750364416 B