Appendix
21.5
21.5 Total Current Consumption Interfaces
The total current consumption at 5 V interfaces must not exceed past 5 A:
Every COM*
= 300 mA, total of 1000 mA
Every USB2.0/USB3.0, USB 3.1
= 500 mA/900 mA, total of 3 A
Every USB (HUB)
= 500 mA, total of 2 A
TFT/LCD display
Max. 5 A @ 5 V
The total current consumption at 12 V interfaces must not exceed past 5 A:
Every COM*
= 600 mA, total of 900 mA
Every PoweredUSB
Every PoweredUSB 12 V*
= 1.5 A, total of 2 A
= max. 3 A
TFT/LCD display
Max. 5 A @ 12 V
The 24 V PoweredUSB interface is provided for the operation of DN retail thermal printers. The peak
load is configured accordingly. The maximum average continuous current strength must not exceed 2 A.
DN retail printers can be set to 90 Watt.
For thermal reasons, the power consumption of additionally implemented PCI and PCIe controllers is
limited per slot to 10W and in total to 20W.
01750341829F
21-5