7.3 QUICK SETUP
Step
Indication
Action
1
Check direction
of motor rotation:
Use the UP button to move the door in the “OPEN“
direction. Check that the door is moving in the “OPEN“
direction.
The door stops automatically. Release the button and
when the direction is OK, press UP. If wrong, press
DOWN. The controller automatically changes
the direction of motor rotation.
2
Reference run:
To initialize the teach-in run, the reference point must first
be approached. Note the following:
Door position before Pre close limit switch = door moves
in direction CLOSED.
Door position behind Pre close limit switch (reference
switch), i.e. limit switch is actuated = door moves in
direction OPEN.
If the reference point has been detected (Pre close limit
switch), the display changes from “Reference Run By
Deadman“ to “Press Menu-Enter To Continue“.
Press now MENU/ENTER.
3
“fully open“
Position:
Use the UP key to move the door to the fully open
position. The door stops automatically as soon as the limit
switch in OPEN has been reached.
Save the position by pressing MENU/ENTER.
4
“fully closed“
Position:
Now move the door to the fully closed position with the
DOWN key. The door stops automatically as soon as the
limit switch in CLOSED has been reached.
Save the position by pressing MENU/ENTER.
»