37
DICTATOR Technik GmbH · +49 (0)821 246730 · [email protected] · www.dictator.de · 22.06.22
Technical manual: SQUARE 940-2
Options
Description
Auto Close
Set the auto-close timer value to be used when the door is in the completely
open position.
Run Timer
The maximum time a door movement may take before the “timeout“ error is
set. The time should be set to 5 seconds longer than the set time required to
close the door. During the reference run the time is 3x the normal time.
Timer 1
Timer Value: Set the timer value for the following timers. The time base is
1/10 seconds.
Timer functions: Set the function for the timer as shown in the following table.
Timer 2
Timer 3
Timer 4
Timer functions
Description
No Function
Timer has no function.
Auto Close Timer
Part 1
Auto close of “Part open 1“.
Safety Close
If the safety edge or light barrier has been activated, the auto closing time is
changed to this safety closing time instead.
Pre Warn Time
Used in combination with the output function. Timer starts when the auto close
timer reaches the set warning time.
Delay To Open
The opening command is delayed by the set time before the door opens.
Delay To Close
The closing command is delayed by the set time before the door closes.
Delayed Door
Closed
Starts when the door is fully closed - Activates the Delayed Door Closed output
function when it expires.
Auto Open
Timer
Opens the door automatically as soon as it is fully closed and the timer has
expired. Used for the cycle test.
5.12.1 Timer