OPERATOR’S MANUAL
ISO
6
Version 4 Quick Start Guide
CONTROLS / 21
6011662 Rev B
1. Fill the tank and weigh the load.
2. Activate the calibration routine.
3. After spraying a few hundred gallons, but before the load is
empty, stop the calibration.
4. Weigh the load again.
5. Calculate gallons dropped.
PERFORM A LIQUID FLOW CATCH TEST
CAUTION
Tanks must contain material. Be prepared to catch the
material in a container so it can be measured at the end of
the calibration.
1. At the Liquid Control setup screen, press the
K-FACT CAL
button.
2. Enter the Target Ground Speed and Target Flow Rate
to calculate the operation rate.
3. Press the
START
button.
4. Press
STOP
button when container is full.
DANGER
When the START key is engaged, the machine will become
operational. All necessary precautions must be taken to
ensure user safety. Failure to practice all necessary caution
may result in serious injury or death.
5. Enter amount (gallons) dispensed in the Total Amount
Collect field.
6. Press
SAVE
button to accept the selection.
7. The system automatically calculates and saves the new
K-Factor for this material.
Figure 14
K-Factor Calibration
CAUTION
DANGER