
DiBO n.v. 67
7. Malfunction table
At a possible malfunction one can consult the table mentioned below and if you obtain on this basis no solution, we
advise to contact a DiBO technician and/or a recognized DiBO representative.
Malfunction
Cause
Solution
Machine does not start
Battery tension too low
Loads battery
Operation switch “OFF”
Operation switch “ON”
Start engine does not work
Consult an expert
Too few oil in engine casing
Refill oil
Rest malfunctions
Consult an expert
No water pressure
To few water inlet
Repair water inlet
Filter stuffed-up
Clean/replace filter cartridge
Instable and to weak pressure
Air in water supply (leaks in water
supply)
Put machine completely without
power! Repair leaks in supply.
Nozzle or lance stuffed-up or worn-
out.
Clean or replace
Pressure regulator defect
Consult an expert
Rest malfunctions
Consult an expert
HP pump pulse
Leak or congestion in supply conduit
Clean/replace/repair
To much air present
De-aeration of cleaner